Installation details: 
Power Supply:

  

  Oceanic  (8.4kW/400Vac.  3  PHASE)    -  This  unit  must  be  connected  to  a  suitable  3  phase 

power supply. This should be done by a qualified electrician.  
 

Water Pressure:

 5 - 50 psi (min.-max.) 35 - 345 kPa (min.-max.) 

 

Installation procedure: 

  Fit a stop Valve on a cold water line and attach a 3/4" BSP male fitting,  

  (e.g. 3/4" x 1/2" 311 or washing machine type stop valve). 

  Connect  straight  tailpiece  of  the  hose  to  the  stop  valve  fitting.  Make  sure  that  the  pre -

attached sealing washer is fitted. 

  Turn  on  the  water  to  flush  any  impurities,  dust  etc  from  the  inlet  hose  and  water  pipe.  Allow 

several gallons through. 

  Connect  right-angled  tailpiece  of  the  hose  to  the  inlet  valve  of  the  boiler  (again  3/4"  BSP). 

Make sure the sealing washer is fitted here also. 

  Turn on water and check for leaks. 

  Connect to a suitable power supply. 

 

Font Installation: 

 

 
Counter Drilling:

 

Holes  need  to be drilled in  the counter for the mounting bolts  (6-10mm diameter). 4  holes are in 
the  base  plate.  Please  use  the  dimensions  shown  below.  A  large  hole  needs  to  be  drilled  in  the 
counter (35mm diameter) for routing feed pipes and control wires.  

 
Font Assembly: 

Turn  off  the  machine.  The  fonts  are  attached  to  the  drilled  counter  with  4  x  M6  nuts,  bolts  and 
washers  (all  parts  are  found  in  the  drip  tray).  A  rubber  grommet  fits  into  the  font  base  plate  to 
prevent the wire cutting against the steel edge. The silicone hose from the boiler is secured to the 

Summary of Contents for OCEANIC 8.4kW

Page 1: ...Limited 63d Heather Road Sandyford Industrial Estate Dublin 18 Marco Beverage Systems Limited Shire House Strixton Manor Strixton Wellingborough Northants NN29 7PA Ireland Tel 353 0 1 295 2674 Ireland Fax 353 0 1 295 3715 email sales marco ie www marco ie UK Tel 44 0 2072 744 577 UK Fax 44 0 2079 788 141 email sales marco bev co uk www marco bev co uk ...

Page 2: ...eral gallons through Connect right angled tailpiece of the hose to the inlet valve of the boiler again 3 4 BSP Make sure the sealing washer is fitted here also Turn on water and check for leaks Connect to a suitable power supply Font Installation Counter Drilling Holes need to be drilled in the counter for the mounting bolts 6 10mm diameter 4 holes are in the base plate Please use the dimensions s...

Page 3: ...pense time for less quick font button click will set the font back into push hold mode After the volumes are set properly press the tactile button on the timer board once again Both pumps will turn on and off for 0 1s twice that will be heard as a double click meaning that the timer is out of calibration 3 Please note that there is no given order which font is to be calibrated first in fact they m...

Page 4: ...water boiler manufacturers service calls resulting from limescale are not covered by warranty Fitting a scale reducer is recommended especially in hard water areas This can reduce the build up of scale but may not stop it altogether The frequency that descaling is required depends on the local water supply hard water areas need more attention A scale reducer can reduce the build up of scaling but ...

Reviews: