1900082                                                                   REV.1 

 

 

Page 3 of 4 

black  fitting  from  the  font  using  the  supplied  hose  clip.  Connect  the  black  wire  coming  from  the 
water boiler  to the wires coming from the  font base (it doesn’t matter which wire goes to  which 
connector on the font) 

 

Operating boiler for the first time: 

Turn the water on at stop valve and switch the power on at the switch on the front of the machine.  

1.  Timer board works by default (after flashing) in "push & hold" mode.  
2.  To set a time dispense please follow the calibration procedure:  

 

Open the service door on the front panel 

 

Once the machine is full and heated up (the status LED glowing green) press the tactile switch 
on the left control PCB (timer board). 

 

Both pumps will turn on and off for 0.1s - that will be heard as a click meaning that the timer is 
in the calibration mode. 

 

Place an empty cup (measuring jug) underneath the fo nt that is to be calibrated. 

 

Press and hold a font button until you get the right amount of water. The water does not have 
to be dispensed in a single push - if the button is pressed few times the overall time will be 
used. 

 

Do the same action with the other font if needed. If only one font is calibrated, settings for the 
other will not be altered. 

 

The minimum time possible for the time dispense operation is 1s. Setting the dispense time for 
less (quick font button click) will set the font back into "push & hold" mode. 

 

After the volumes are set properly press the tactile button on the timer board once again.  

 

Both pumps will turn on and off for 0.1s twice - that will be heard as a double click meaning 
that the timer is out of calibration. 

3.  Please  note  that  there  is  no  given  order  which  font  is  to  be  calibrated  first  -  in  fact  they 

may be calibrated at once or only one may be calibrated (leaving the settings of the other 
unaltered).  

4.  If  there  is  no  response  from  the  user  in  the  calibration  mode  (none  of  the  font  buttons 

pressed) for  more  than 25 seconds  the timer will end the calibration (double pump "click" 
will be heard). 

5.  The maximum allowable  time of  the dispense is 25 seconds. Any  longer times  will be cut 

down to 25 seconds.  

6.  The resolution of the time measure ment is 0.1s. 
7.  The timer board  has its own clock on board therefore power  line  frequency is not  used to 

measure the time. 
 

Troubleshooting: 

The  Ready/Status  light  signals  various  errors  or  problems.  A  cycle  of  red  flashes  indicates  an 
error.  
 

Status/Diagnostic light guide: 

Status light

 

Symptom

 

Action required 

Water level below elements - 

Normal when machine first fills. 

Check water supply , if this is OK 

then call service agent. 

Temperature sensor failure o/c 

Call service agent 

Water not heating 

Call service agent 

Temperature sensor failure s/c 

Call service agent 

Machine not filling 

Check water supply , if OK then call 

service agent. 

 

Summary of Contents for OCEANIC 8.4kW

Page 1: ...Limited 63d Heather Road Sandyford Industrial Estate Dublin 18 Marco Beverage Systems Limited Shire House Strixton Manor Strixton Wellingborough Northants NN29 7PA Ireland Tel 353 0 1 295 2674 Ireland Fax 353 0 1 295 3715 email sales marco ie www marco ie UK Tel 44 0 2072 744 577 UK Fax 44 0 2079 788 141 email sales marco bev co uk www marco bev co uk ...

Page 2: ...eral gallons through Connect right angled tailpiece of the hose to the inlet valve of the boiler again 3 4 BSP Make sure the sealing washer is fitted here also Turn on water and check for leaks Connect to a suitable power supply Font Installation Counter Drilling Holes need to be drilled in the counter for the mounting bolts 6 10mm diameter 4 holes are in the base plate Please use the dimensions s...

Page 3: ...pense time for less quick font button click will set the font back into push hold mode After the volumes are set properly press the tactile button on the timer board once again Both pumps will turn on and off for 0 1s twice that will be heard as a double click meaning that the timer is out of calibration 3 Please note that there is no given order which font is to be calibrated first in fact they m...

Page 4: ...water boiler manufacturers service calls resulting from limescale are not covered by warranty Fitting a scale reducer is recommended especially in hard water areas This can reduce the build up of scale but may not stop it altogether The frequency that descaling is required depends on the local water supply hard water areas need more attention A scale reducer can reduce the build up of scaling but ...