background image

11

Mareli Systems

CHRONO

This Manu allows selecting the programming modalities and and the Ignition/Extinguishing time slots.

 

Disable

 

 

Daily

 

Weekly

 

Week

-

End

 

 

Modality

 - It allows selecting the disired modality, or disable all set programming.

1. Enter modification mode through the key 

P3

.

2. Select the chosen modality (Daily, Weekly or Week end).

3. Enable/disable chrono modality through the keys 

P2

.

4. Save the settings through the keys 

P3

.

Programming

The system includes three type of programming: Daily, Weekly, Week end. 

After selecting the desired kind of programming:

1. Select the programming time through the keys 

P4/P6

.

2. Enterthe adjustment modality (selected time will be flashing) through the keys 

P3

.

3. Change the time via keys  

P4/P6

.

4. Save the programmong with the keys 

P3

.

5. Enable (a “V” is displayed) or disable the time slot (a “V” is not displayed”) by 

pressing the keys 

P5

.

Daily

Select the day of the week to program and set the ignition and extinguishing times.

Programs around midnight

Set the clock On of the previous day at the desired time: Ex. 20.30

Set the clock of OFF of the previous day at:  23:59

Set the clock On of the following day at  00:00

Set the clock of OFF of the following day at the desired time: Ex. 6:30

The system turns on at 20.30 on Tuesday and turns off at 6.30 on Wednesday

Weekly

The programs are the same for all days of the week.

Week-end

Choose between 'Monday-Friday' and 'Saturday-Sunday' and then set the switching 

on and off times.

 

 

Monday 

 

 

    ON             OFF 

  09:30           11:15  V 

  00:00           00:00 

  00:00           00:00 

Monday

____________ 

Tuesday 

Wednesday  

Thrusday 

Friday

 

Mon-Fri 

Sat-Sun 

 

USER MENU 2

Menu is accessed by pressing the 

P3 

buttons for 3 seconds .

Keyboard Settings

 

Time and Date

 - Used to set the day, month, year and current time.

Language

 - Menu to modify the language of the LCD board.

Keyboard Menu
Set Contrast

 - Menu used to regulate the display contrast.

Set Minimum Light

 - Menu used to regulate the lighting of the display when the command aren’t used.

Keyboard Address - 

It allows to change the address of the RS485 node. In the RS485 bus it is not possible to 

have more nodes with the same address. It is possible to configure the keyboard as local or remote by changing 

the address (16 for local , 17 for remote).

Node List - 

This menu shows: communication address of the board, typology of the board, firmware code and 

firmware version. Data are not modifiable. The typologies of board that can appear are:

MSTR - Master; 

INP - Input ;  

KEYB - Keyboard; 

 

OUT - Output;

CMPS - Composite;  SENS - Sensor; 

COM - Communication;

Acoustic Alarm 

- It allows to enable or disable the acoustic alarm of the keyboard.

Summary of Contents for PS 24

Page 1: ...PS 24 Pellet stove Assembly and exploitation manual The present stove is designed and manufactured according to Standards BNS Bulgarian National Standard EN 14785 2006 Mareli Systems ...

Page 2: ...errorsormisbehaviouroromissions Anyinterventionorreplacementthatismadebyunauthorizedpeopleorusingnonoriginalspareparts fortheproductcanberiskyfortheuserandreleasethecompanyfromallliability Most surfaces of the stove are extremely hot the door handle glass flue pipe etc Avoid contact with thesepartsbeforeassuringyourselfthatyouustemperatureresistantglovesaswellassuitabletemperature resistantinstrum...

Page 3: ...se unstable and inconsistent work of the stove What are the pellets The pellets are produced by compressed wooden waste left from the production of various furni ture sawmills and others This type of fuel is environmentally friendly because in the production process no agglutinate agents glues resins and others are added Actually the integrity of the pellets is guaranteed by the lignite a natural ...

Page 4: ...d not less than 20 cm from both sides and the rear side If flammable materials or constructions are present the distance between them and the stove must be at least 80 cm When assembling the stove make sure that the joints between the separate pipes and the chimney socket are well insulated A smell on first start up of the stove is due to the burning of the paint The stove is painted with thermal ...

Page 5: ...ating with solid fuel stove electrical boiler equipped with water serpentine and a solar panel For economy and efficiency of the system and a constant avail ability of cheap hot water a qualified assembly of the automatic shifter controlling the thermal flows to and out of the solar panel and the boiler is required Chart 2 shows a one storey heating with a compulsory circulation The advantage of t...

Page 6: ...ding 3 m More than four direction shifts are forbidden including the cases where a T shaped element is used The duct components must be airtight and to be insulated if extending outside the premises in which the fireplace is installed The duct components must allow a soot cleaning The duct components must have a constant section A section change is allowed only in the chimney joint Chimney The chi...

Page 7: ...ean it from soot When removed fuel pot at the bot tom of the combustion chamber opens a hole designed for the accumulated ash Collect ashes in the ashtray and return fuel pot in place and then close the door The fireplace is ready for operation Cleaning of flues and chimneys are conducted once every 1 5 tons of fuel used Cleaning of flues 1 Open the top cover of the fireplace by pulling it up 2 Lo...

Page 8: ...ing risks Risks of spreading combustion outside fireplace opening the door of the chamber of the fireplace may fall hot burning particles as hot ash and small particles burning coal which could lead to a fire in the heated room It is therefore necessary that the product always works with a tightly closed door It can only be opened when the product has completely cooled down Risks of burns caused b...

Page 9: ...stat open flame return from the brazier Er07 Encoder Error The error may occur due to lack signal from Encoder Er08 Encoder Error The error can occur due to problems of adjustment of the number of revolutions Er09 Water pressure low Er10 Water pressure high Er11 Clock Error The error occurs due to problems with the internal clock Er12 Extinguishing for ignition failure Er15 Extinguishing due to po...

Page 10: ...cond case the user selects the desired power On the left side of the display are signalled the combustion modality A automatic combustion M manual combustion and the working power of the system Recipe Menu to select the combustion recipe The maximum value is the number of recipes visible to the user Auger Calibration It allows to modify the value set in firm of Auger s speed or On times The values...

Page 11: ...g day at the desired time Ex 6 30 The system turns on at 20 30 on Tuesday and turns off at 6 30 on Wednesday Weekly The programs are the same for all days of the week Week end Choose between Monday Friday and Saturday Sunday and then set the switching on and off times Monday ON OFF 09 30 11 15 V 00 00 00 00 00 00 00 00 Monday____________ Tuesday Wednesday Thrusday Friday Mon Fri Sat Sun USER MENU ...

Page 12: ...12 Mareli Systems FIRST CONFIGURATION First select the plumbing installation parameter P26 from the Enable menu of the Technical menu ...

Page 13: ...13 Mareli Systems ...

Page 14: ...14 Mareli Systems ...

Page 15: ...15 Mareli Systems ...

Page 16: ...they are due to printing or transcription errors We reserve the right to make any change that appears to be necessary or useful without harm the essential characteristics Mareli Systems MareliSystems IndustrialZone Simitli 2730 RegionBlagoevgrad Bulgaria info mareli systems com www mareli systems com ...

Reviews: