Page 1: ...OPERATING MANUAL OPERATING MANUAL OPERATING MANUAL OPERATING MANUAL SMALL ANIMAL VERTICAL DISPLAY SYSTEMS DISPLAY SYSTEMS ...

Page 2: ......

Page 3: ...Installation Instructions Pages 4 6 Operation Slide out Drawers Pages 7 9 p g Odor Control Cartridge Replacement Page 10 Fluorescent Lamp Replacement Page 11 W t B ttl R l t d P 12 Water Bottle Replacement and Removable Divider Procedures Page 12 Troubleshooting Guidelines Page 13 Warranty Page 14 Warranty Page 14 ...

Page 4: ... do not contact moving parts or hot parts such as heaters reflectors lamp bulbs etc 4 Always turn off power at main disconnect when not in use before putting on or taking off parts and before cleaning Never yank a cord to pull a plug Grasp the plug and pull to disconnect 5 Do not use an appliance for other than intended use The use of attachments not recommended or sold by the appliance manufactur...

Page 5: ...or easier cleaning and better hygiene Enclosures slide out like no other system for cleaning purposes better viewing of species and alternate capture Also included are removable dividers that allow you to use an entire tank for larger species or just to make a more spacious enclosure These enclosures are ventilated with perforated closing lids and vents for optimal use of Ventilation System that i...

Page 6: ...chanical Key Key Fob Option Frame Powder Coated Steel Drawer Glides 150 lbs Glass 3 16 Tempered Doors Extruded Aluminum d l ELECTRICAL Voltage 120 VAC 60Hz 5 AMP LIGHTING Lights T8 32 watt Florescent Side Panels Impact Resistant ABS AIR CIRCULATION Blower 150 CFM Filter 60 Square Inches BUYER SUPPLIED CONNECTIONS Cord Connection 120 VAC 60 Hz 15 AMP APPROVALS Electrical Safety ETL Listed Seismic C...

Page 7: ...nnel lock pliers Two levels One large one small Note A specially designed dolly is available for rent from Marineland for easier movement of the MaRS units Step 1 Position Small Animal System Assistance of at least one other person is recommended to roll the Small Animal unit into the installation area B Carefully place the Small Animal unit in an upright position Make sure the unit is straight an...

Page 8: ... Position Small Animal System With the assistance of at least one other person roll the small animal unit back into the installation area Carefully tilt the Small Animal System to clear the anchor bolts and place the i i i h i i unit in an upright position NOTE To ensure easier installation remove front bottom Kick Panel Do not install provided end panels until the unit has been installed Step 5 L...

Page 9: ...e front tape where the Vertical extrusion goes D C Step 9 Install System Vertical Extrusions Peel the remaining double sided tape included on the narrow surfaces of the end front framework E Press Aluminum Vertical Extrusion firmly into place F E F Step 10 Plug in Small Animal System Have the Ventilation Lighting and Door Locking System connections plugged into p g y p gg the appropriate receptacl...

Page 10: ...es 2 1 not disturb the small animals within the enclosures If your purchase included a Key Fob sold as an option pressing the Key Fob for a second or two will allow you around 8 seconds to open one drawer When ready to close the drawer gently push the drawer away from you smoothly and until you hear it y y y y lock Caution Make sure that people are not near the drawer when closing to prevent injur...

Page 11: ...or cleaning purposes picture C Note The back portion of the slide out Lid is stationary to deter escape 4 As you slide the lid toward you use the 2 hooks on the bottom side of the lid to allow the lid to hang on the front of the tank picture D 5 When done vending animals remember to replace the hanging lid before sliding in drawer Slide the lid in until the clip engages picture E drawer Slide the ...

Page 12: ...imal within the enclosure Add the appropriate amount per the tank dimensions Most substrates have an amount recommendation on the product Note It s recommended that enclosures containing a large amount of substrate be cleaned within the small animal unit If you decide to remove and carry the enclosure away from the Small Animal unit Handle the enclosure securely to id id t d If il bl i t Service c...

Page 13: ...tion issues Step by step instructions 1 Use an appropriate ladder to reach the Ventilation System above Small Animal Display System 2 Open access cover and pull up cartridge to remove 2 1 2 3 Insert new Odor Control Cartridge and close access cover 3 4 and 5 To order Odor Control Cartridges please call Marineland at 800 576 6277 3 4 Odor control cartridges Ventilation Filter Cartridge Part MZ0412 ...

Page 14: ...re tank within This procedure makes it easier to replace lamps 3 Remove fluorescent lamp Gently twist 90 degrees and push backward and out from mounted station slots Discard according to established environmental procedure 4 Replace discarded lamps with new lamps Gently insert ends into slots and push up and forward or up and back until lamp fits securely in place 5 After replacing the lamp turn o...

Page 15: ...e Small Animal System The Water Bottle Holder is made to hold a variety of water bottles Removable Divider Procedures Removable Divider Procedures Removable Divider Procedures To remove the divider gently pull the divider up with both hands holding it on both sides Then gently push the divider to one side to remove off the rail Take to divider out of l h d l enclosure Reverse the procedure to repl...

Page 16: ...lean slide brackets Also use a small portable vacuum to removed dust and debris Fluorescent Lamp not coming on To replace the fluorescent lamp shut off the light power by unplugging the unit NEVER change lamps on fixture while it s on Open Drawer and carefully remove enclosures within This lamps on fixture while it s on Open Drawer and carefully remove enclosures within This procedure makes it eas...

Page 17: ...fic Time will be responded to within 24 hours Please have your manual and the system serial number ready In most cases the problem will be resolved by a simple maintenance procedure recommendation or repair authorization Upon authorization and in instances where t id i l t f t i M i l d ill b b ll outside repair or replacement of parts is necessary Marineland will absorb all appropriate costs Dama...

Page 18: ...ve g y p q p number from 7a m 5p m Monday Friday CONSUMABLES ITEMS 1 VENTILATION FILTER CARTRIDGE 6 PACK MZ0412 SERVICING ITEMS ADDITIONAL ITEMS Z090618 6 11 All Fluorescent Lamps and Ultra Violet Lamps contain mercury Dispose of Properly A Division of The United Pet Group Moorpark CA 93021 2006 Marineland Printed in the U S A Marineland and MaRS are trademarks of United Pet Group ...