User’s Guide 

232 - RS-232 settings 

 232d 

Output 

Disabled 

 

 

232E Output 

Enabled

   

 

  

 300 

300 

baud  

 600 

600 

baud  

 1200 

1200 

baud 

 2400 

2400 

baud 

 4800 

4800 

baud 

 

9600 9600 

baud 

 

7-1E 

7 data bits, 1 stop bit, even parity 

 

 

7-1o 

7 data bits, 1 stop bit, odd parity 

 

 

7-2E 

7 data bits, 2 stop bits, even parity 

 

7-2o 

7 data bits, 2 stop bits, odd parity 

 

7-2n 

7 data bits, 2 stop bits, no parity 

 

8-1E 

8 data bits, 1 stop bit, even parity 

 

8-1o 

8 data bits, 1 stop bit, odd parity

 

 

8-1n 

8 data bits, 1 stop bit, no parity 

 

8-2n 

8 data bits, 2 stop bits, no parity

 

 

Ft F 

Full data (n units)

 

 

Ft n 

Numeric data only 

 

out - Outputs selection (other than RS-232) 

 

SP d 

Set point outputs disabled 

 

SP E 

Set point outputs enabled 

 

bcd d 

Mitutoyo BCD output disabled 

 

 

bcd E 

Mitutoyo BCD output enabled 

 

nPOL 

Mitutoyo readings without polarity (absolute value) 

 

POL 

Mitutoyo readings with polarity; positive for  

 

 

compression (CW),  negative for  tension (CCW) 

 

 

 

Et d 

External trigger disabled

 

 

Et E 

External trigger enabled in edge mode 

 

Et L 

External trigger enabled in level mode 

 

EtHL 

Data capture during high to low transition of trigger signal

 

EtLH 

Data capture during low to high transition of trigger signal 

 

Aout - Automatic output (RS-232) 

 

no Automatic 

output 

disabled

 

 

Every sample transmitted 

 

Every 2nd sample transmitted 

 

Every 4th sample transmitted 

 

Every 8th sample transmitted 

 

16 

Every 16th sample transmitted 

 

32 

Every 32nd sample transmitted 

 

64 

Every 64th sample transmitted

 

 

128 

Every 128th sample transmitted 

 
AoFF - Automatic shutoff settings 

 

no Disabled 

Summary of Contents for BGI

Page 1: ...DIGITAL FORCE TORQUE INDICATOR Model BGI User s Guide...

Page 2: ...ed For additional information or answers to your application questions contact us and our technical support and engineering teams will be eager to help you Thank you again for your purchase and happy...

Page 3: ...in parentheses For a detailed description of the secondary functions see Section 3 POWER ENTER Turns power on and off UNITS Selects units of measurement ZERO Zeroes any tare value up to the full capac...

Page 4: ...has several features with programmable options allowing many user specified choices In order to access the configuration menu perform the following 1 Turn off the indicator 2 Press and hold MODE 3 Tu...

Page 5: ...Set point outputs enabled bcd d Mitutoyo BCD output disabled bcd E Mitutoyo BCD output enabled nPOL Mitutoyo readings without polarity absolute value POL Mitutoyo readings with polarity positive for...

Page 6: ...gs A E Average mode enabled A d Average mode disabled dEL Initial delay prompt At Average time prompt trF Trigger force torque value prompt CAL Calibration See Section 10 4 FILTERS For maximum flexibi...

Page 7: ...trigger signal returns to its original state Please refer to the diagram for connection details and to Section 3 for configuration information 6 SET POINTS This feature is useful for tolerance checkin...

Page 8: ...The process of averaging begins as soon as the programmed trigger reading is reached and is indicated by a flashing A The conclusion of the test is indicated by an alternating A and the calculated val...

Page 9: ...e PKCW Peak Clockwise mode PKCCW Peak Counter Clockwise mode CLR Clear peaks start a new average or external trigger test Z Zero display and perform the CLR function Request the displayed reading C Re...

Page 10: ...ngs and features using the same abbreviations as the commands to set them Any detected errors are reported back by means of the following error codes 10 Illegal command 11 Not applicable e g SPHn comm...

Page 11: ...transmitted if DATA is pressed during the average computation while in the Average mode or during the input scanning in the External trigger mode Mitutoyo BCD This output is useful for connection to...

Page 12: ...eration In some cases the display will show nnnn or uuuu to indicate excessive or insufficient calibration weight This can be caused by incorrect weights tare weight of over 10 of the full capacity or...

Page 13: ...cts in workmanship and materials Mark 10 Corporation will at its option repair or replace or refund the purchased price of goods found to be defective This remedy shall be the buyer s sole and exclusi...

Page 14: ...standard line of products we can provide modifications and custom designs for OEM applications Our engineering team is eager to satisfy any special requirements Please contact us for further informati...

Reviews: