Series TT02 Digital Torque Tool Testers
User’s Guide
10
If two set points have been enabled, they are displayed in the upper left corner of the display. If only one
set point has been enabled, the word “OFF” appears in place of the value. If no set points have been
enabled, the upper left corner of the display will be blank.
When set points are enabled, the following indicators are shown to the left of the primary reading:
– the displayed value is greater than the upper
force limit (NO GO HIGH)
– the displayed value is between the limits (GO)
– the displayed value is less than the lower force
limit (NO GO LOW)
Note:
Set point indicators reference the displayed reading, not necessarily the current live load.
8.2.1 Set Point Outputs Schematic Diagram
9 BREAK DETECTION
The break detection function identifies when the tool has clicked, slipped, or stopped – or applications in
which the torque value has reached a peak, then dropped. Upon detection of the break, the tester can
perform several automatic functions, as follows:
1. Transmit the peak reading (Auto Output).
2. Save the peak value to memory (Auto Storage).
3. Zero the primary and peak readings (Auto Zero).
4. Toggle a pin.
Break detection functions and settings are configured from a central location, and apply to any mode in
which it is enabled. Refer to the
Operating Modes
section for details on configuring each mode.
9.1 Configuration
To enable Break Detection and configure the automatic functions, select
Break Detection
from the main
menu. The display appears as follows: