11.2 Statistics
Statistical calculations are performed for the saved values. Calculations include number of readings,
minimum, maximum, mean, and standard deviation.
11.3 Output Data
Press
ENTER
to output data to an external device. The display will show, “SENDING DATA…”, then
“DATA SENT”. If there was a problem with communication, the display will show, “DATA NOT SENT”.
Saved data can be downloaded by some Mark-10 data collection programs. Refer to their respective
user’s guides for details.
11.4 Output Statistics
Press
ENTER
to output statistics to an external device. The display will show, “SENDING STATS…”, then
“STATS SENT”. If there was a problem with communication, the display will show, “STATS NOT SENT”.
11.5 Output Data & Stats
Press
ENTER
to output data and statistics to an external device. The display will show, “SENDING
DATA”, then “SENDING STATS…”, then “DATA SENT”, then “STATS SENT”. If there was a problem with
communication, the display will show, “DATA NOT SENT” and/or “STATS NOT SENT”.
11.6 Clear All Data
Press
ENTER
to clear all data from the memory. A prompt will be shown, “CLEAR ALL DATA?”. Select
Yes
to clear all the data, or
No
to return to the sub-menu.
For output of data and/or statistics, RS-232 or USB output must be enabled. Data formatting is
<CR><LF> following each value. Units can be either included or excluded. Output of data via the Mitutoyo
output is possible, however, output of statistics is not. Refer to the
Communications and Outputs
section for details.
Note:
Data is not retained while the tester is powered off. However, the tester protects against accidental
or automatic power-off. If manually powering the instrument off, or if the inactivity time limit for the
Automatic Shutoff
function has been reached, the following warning message appears:
If no option is selected, this screen will be displayed indefinitely, or until battery power has been depleted.
12 COMMUNICATIONS AND OUTPUTS
Communication with the TT02 tester is achieved through the micro USB or 15-pin serial ports located in
the rear of the housing, as shown in the illustration in the
Power
section. Communication is possible only
when the tester is in the main operating screen (i.e. not in a menu or configuration area).
12.1 Serial / USB
To set up RS-232 and USB communication, select
Serial/USB Settings
from the menu. The screen
appears as follows:
*** WARNING ***
DATA IN MEMORY
WILL BE LOST
CANCEL
POWER OFF
www.
.com
information@itm.com
1.800.561.8187