1 OVERVIEW
1.1 List of included items
Qty. Part
No.
Description
1
MTT02-12 /
MTT02-25 /
MTT02-50 /
MTT02-100
Series TT02 digital torque tool tester
1
08-1026
Battery (inside the instrument)
1
-
Certificate of calibration
1 09-1165
USB
cable
1
-
Resource CD (USB driver, user’s guides, MESUR
TM
Lite software,
MESUR
TM
gauge DEMO software, User’s Guide)
1
ST001
Bench mounting kit (optional)
1 ST002
Carrying
case
(optional)
1
AC1066-1
Rundown fixture (optional)
1
AC1066-2
Rundown fixture (optional)
1.2 Safety / Proper Usage
Caution!
Note the torque tester’s capacity before use and ensure that the capacity is not exceeded.
Producing a torque greater than 150% of the tester’s capacity can damage the internal sensor. An
overload can occur whether the tester is powered on or off.
The tester is designed primarily for the testing of torque tools, although other items can be tested as well.
Items that should not be used with the tester include potentially flammable substances or products, items
that can shatter in an unsafe manner, and any other components that can present an exceedingly
hazardous situation when acted upon by a load.
The following safety checks and procedures should be performed before and during operation:
1. Never operate the tester if there is any visible damage to the AC adapter or the tester itself.
2. Ensure that the tester is kept away from water or any other electrically conductive liquids at all
times.
3. The tester should be serviced by a trained technician only. AC power must be disconnected and
the tester must be powered off before the housing is opened.
4. Always consider the characteristics of the sample being tested before initiating a test. A risk
assessment should be carried out beforehand to ensure that all safety measures have been
addressed and implemented.
5. Wear eye and face protection when testing, especially when testing brittle samples that have the
potential to shatter under force. Be aware of the dangers posed by potential energy that can
accumulate in the sample during testing. Extra bodily protection should be worn if a destructive
failure of a test sample is possible.
6. In certain applications, such as the testing of brittle samples that can shatter, or other applications
that could lead to a hazardous situation, it is strongly recommended that a machine guarding
system be employed to protect the operator and others in the vicinity from shards or debris.
7. When the tester is not in use, ensure that the power is turned off.