DigiConvert Operating Instructions
Copying this document, or disclosing it to third parties is not allowed without our approval. This document must not be used in any abusive way by the receiver or third
parties. Fe Vogt GmbH
DigiConvert Operating Instructions
10 of 79
6.3.
Warning Light System for the Entire Machine
Signal column at the operator terminal
Status red
The red status means:
➢
Blinking: EMERGENCY STOP mode active, acknowledgement with the emergency stop reset
button necessary
o
The blue lamp of the emergency stop reset button shines continuously
➢
Permanently red: The machine is in STOP mode
Status yellow
The yellow status means:
➢
Blinking: PREP status has not yet been reached
➢
Permanently yellow: The machine is in PREP mode
Status green
The green status means:
➢
Blinking: Although the machine is in START mode, it has not yet reached the desired speed.
➢
Permanently green: The machine is in START mode, the desired speed is reached.