DigiConvert Operating Instructions
Copying this document, or disclosing it to third parties is not allowed without our approval. This document must not be used in any abusive way by the receiver or third
parties. Fe Vogt GmbH
DigiConvert Operating Instructions
69 of 79
Here, the operator has the following possibilities:
•
Activating / deactivating the assembly
•
Switching on the electrical shaft between the punch and the translative module
•
Entering the lead in [%], when regulation is at lead.
Activating / deactivating the drive
Press the button to deactivate the drive.
Press the button again to reactivate the drive.
Homing
Press the button to home the drive. Press and hold the button for at least 2 seconds.
Switching on the electrical shaft
Press the button to switch on the electrical shaft. Press and hold the button for at least 2
seconds.
The icon indicates whether the electrical shaft is ON or OFF.
.
Selecting the lead
Here you can select the lead in the range -20 ... 20%. The increment is 0.01%. After you have pressed
the button you can enter a figure at the numerical keypad. Recommendation: This value should be 0%
at the start of a new product.
Input is only possible when the register is completely switched off or the register lead regulator is
switched off.
Jogging in neg. direction / jogging in pos. direction
Use these buttons to jog this axis individually at the JOG direction of the individual axis (selectable in
the configuration menu). The yellow background shows the actuated state. Touching the button briefly
performs a correction with fine setting. Pressing and holding the button for more than 2 seconds
performs a correction with coarse setting.
The values for fine and coarse jogging can be edited.