Here, the operator has the following possibilities:
•
Activating / deactivating counter functions
•
Selecting the count station
•
Specifying item length in web run direction
•
Number of items across the web
•
Items per line
•
Items web width
•
Running metre
•
Button "Set total counter to 0"
•
Button "Set current counter to 0"
Counter is:
Use this button to activate or deactivate the counter functions.
Count station:
The most precise measurement of the metres is possible at the pulling stations. Here you can select
the station at which you want to measure.
In stations that are not operated true to register, the quantity is calculated on the basis of the running
meters. This value cannot be guaranteed without any limitation since the running meters can vary
slightly over a longer distance (due to slip, different material, etc.).
Recommendation: The count station should be true to register, such as a punching station.
Settings of the part counter
When you select the punch as count station, the settings of the part counter are taken automatically
from the punch submenu. When you select a different station, the next two input boxes are released.
Item length in web run direction
Specify the length of an item in web run direction here. The length to be entered here is the distance
between the start position of an item and the start position of the next item, including the width of the
stays.
Item length across the web run direction
Enter the number of parallel blanks here.