DigiConvert Operating Instructions
Copying this document, or disclosing it to third parties is not allowed without our approval. This document must not be used in any abusive way by the receiver or third
parties. Fe Vogt GmbH
DigiConvert Operating Instructions
76 of 79
Stop after production quantity
If you want the machine to stop after a given number of metres or items has been reached, enter the
corresponding value here. Entering 0 deactivates the function. The two other parameters are
calculated automatically when you enter a value.
Items per line
Specifies the number of items that shall be produced per line until a stop occurs. Here, the
specification is related to the number of items in web run direction.
Items web width
Specifies the number of items that shall be produced in total until a stop occurs. Here, the specification
is related to the number of items in web run direction, multiplied by the item length across the web run
direction.
Running metre
Specifies the web length that is to be processed until a stop occurs. The specification is calculated
from the number of item lengths in web run direction multiplied by items per line.
Set total counter/ current counter to zero
Press this button to set the counter to zero.
Press the button
to exit the menu