In addition, the machine is equipped with a safe jogging switch. Press and hold the jogging switch to
move the punch at a safe speed up to 5 m/min when the top centre safety hood is open. The entire
machine is moved at this speed when all the outer hoods are closed.
7.2.
Emergency Stop Function
7.2.1.
Triggering Emergency Stop
There are emergency stop switches on the main operator terminal and on the assembly terminals.
Pressing one of the buttons has the following effect:
1. The machine is stopped inside the shortest time possible.
2. The drives are set to the Safe Torque Off (STO) state. This means that no torque-generating
energy can act on a motor, which prevents an unwanted start.
The 24-V control voltage is retained. The servomotors do not produce any torque.
The supply voltage to motors without STO function is switched off.
3. The red lamps of the warning light system and on the main operator terminal blink. The blue
lamp in the reset emergency stop button shines permanently.
7.2.2.
Acknowledging Emergency Stop
To terminate the emergency stop condition, first pull out all pressed emergency stop switches (safe
restart lock). Once this has been done, the blue lamp in the emergency stop reset button on the main
control panel starts blinking. Pressing the emergency stop reset button once is enough.
In addition, acknowledge any occurred alarm messages.
The machine then returns to STOP mode and is ready for a restart.