INSTALLATION, OPERATION MANUAL, MODEL ETP-10E
5.0 OPERATION INSTRUCTIONS
(Continued)
WARNING: When this appliance is installed with casters and is
connected to the supply piping by means of a connector for
moveable appliances, a restraint to prevent damage to the
connector or quick disconnect device should have been installed. If
disconnection of the restraint is necessary, reconnect this restraint
after the appliance has been returned to its originally installed
position.
CAUTION: When the unit is not in use, leave the cooking
compartment doors ajar to prolong the life of the door gasket.
CLEANING
After each period of daily operation
(more frequently as required to maintain cleanliness)
, the
steamer should be thoroughly cleaned by completing the following steps:
1. Remove left and right side pan supports by lifting up and off mounting studs. Remove the
drain screen in the rear of the compartment. Wash with a mild detergent. Rinse and set
aside for reassembly.
2. Wash cooking compartment interior using a mild detergent and water. Rinse and dry
thoroughly.
3. Replace pan supports and drain screen in compartment and leave door open.
DRAINAGE
Cooking Compartment Drainage
The bottom of the cooking compartment is angled slightly toward the rear of the unit. This
assures that any build-up condensate or spills will be directed toward the drain, which is located
at the rear bottom center of the cooking compartment. Any liquid exiting the cooking
compartment runs down the cooking compartment drain tube and into the condensate
tempering tank.
Drip/Spill Trough Drainage
The Pressureless Steam Cooker has a drip/spill trough below the cooking compartment door. It
will catch any condensate gathering on the front of the unit when the door is opened.
Part No. 10309R0
14
2019-05-14