GEnEral troublshootinG GuidE
problEm
probablE causE
rEmEdY
cOOKing inDicATOR
LighT FAiLS TO LighT
WiTh TimER SET
a. main power circuit breaker
tripped.
b. Door interlock switch contacts not
closed.
c. Door interlock switch faulty.
d. indicator light burned out.
e. Faulty timer contacts.
f. Faulty wiring.
a. Locate external circuit breaker for
incoming power and place in On
position.
b. Shut cooker door to close switch
contacts. check alignment of door
with switch.
c. Replace switch.
d. Replace light.
e. Replace timer.
f. inspect condition of wire and
tightness of all connections. correct
as needed.
STEAm FAiLS TO EnTER
cOOKing cOmPARTmEnT
WiTh cOOKing inDicATOR
LighT On
a. Faulty wiring.
a. inspect condition of wire and
tightness of all connections. correct
as needed.
STEAm EnTERS cOmPART-
mEnT cOnTinUOUSLy
WiThOUT ThE cOOKing
OR READy LighT On
a. Standby thermostat not set cor-
rectly.
b. Faulty thermostatic switch.
c. hOLD set on timer.
a. Adjust the thermostat lower.
b. Replace thermostat.
c. Rotate timer knob to ‘OFF’ position.
TimER DiAL nOT TURning
a. Faulty timer motor.
b. Faulty wiring.
a. Replace timer.
b. inspect condition of wire and light-
ness of all connections. correct as
needed.
BUZZER FAiLS TO SOUnD
AT EnD OF TimER SETTing
a. Timer contacts faulty.
b. Buzzer faulty.
c. Faulty wiring.
a. Replace timer.
b. Replace buzzer.
c. inspect condition of wire and tight-
ness of all connections. correct as
needed.
STEAm FLOWS cOnTinU-
OUSLy FROm DRAin LinE
WiTh cOOKER in OPERA-
TiOn
a. cold water not connected.
b. Faulty cooling valve.
c. Faulty wiring.
a. Turn on external shutoff valve.
b. Replace cooling valve.
c. inspect condition of wire and
tightness of all connections. correct
as needed.