ElEctrical fault isolation GuidE
failurE
fault location
1. WiLL nOT OPERATE in EiThER hOLD OR 60-minUTE TimER POSi-
TiOnS.
a. incoming power
b. Timer
c. Door interlock switch
d. Wiring
2. OPERATing in hOLD POSiTiOn BUT nOT in 60-minUTE TimER
POSiTiOn.
a. 60-minute timer
b. Wiring
3. OPERATES in 60-minUTE TimER POSiTiOn BUT nOT in hOLD PO-
SiTiOn.
a. Timer
b. Wiring
c. hold thermostat
4. WiTh cOOK inDicATOR LighT On AnD STEAm EnTERing ThE
cAViTy, TimER DiAL FAiLS TO TURn.
a. hold position set on timer.
b. Timer motor
c. Wiring
5. BUZZER FAiLS TO SOUnD AT EnD OF 60-minUTE TimER mODE.
a. 60-minute timer contacts
b. Buzzer
c. Wiring
6. STEAm FLOWS cOnTinUOUSLy FROm BOiLER DRAin LinE.
a. cooling valve needs replacing
b. Wiring
Summary of Contents for ECO-TECH PLUS ETP-10G
Page 8: ...Wiring Diagrams ...
Page 9: ...Wiring Diagrams ...
Page 10: ...Wiring Diagrams ...
Page 11: ...Wiring Diagrams ...
Page 13: ...june 12 2015 13 etp 5g etp 10g steamer exploded view ...
Page 17: ...june 12 2015 17 etp 5g etp 10g Gas Components ...