5
2.0 INSTALLATION INSTRUCTIONS
GENERAL
The PS-3E and PS-6E steamers are single compartment electric pressureless steam cookers
with an internal electric steam generator that maintains standby water temperature at
approximately 205 F. PS-3E is rated 10 kW. PS-6E is rated 15 kW.
At high altitude locations a lower temperature is required to achieve atmospheric steaming.
Contact your authorized service office to have the thermostat adjusted if the steamer will be
operated at high altitudes.
UNPACKING
This steamer was inspected before leaving the factory. The transportation company assumes
full responsibility for safe delivery. Immediately after unpacking the steamer, check for possible
damage. If the steamer is found to be damaged after unpacking, save the packaging material
and contact the carrier within 15 days of delivery.
Prior to installation, verify that the electrical service agrees with the specifications on the
machine data plate which is located on the left side panel.
LOCATION
Allow space for plumbing and electrical connections. Minimum clearances are 0" on the sides
and 6" (152 mm) on the back for proper air circulation. Allow adequate access for operating and
servicing the steamer, 36" (915 mm) at the front of the steamer and 15" (381 mm) above the
steamer.
LEVELLING FEET (Standard) OR 4" ADJUSTABLE LEGS (Optional)
Thread the four 2" levelling feet shipped in a bag inside the steamer cabinet into the threaded
holes on the bottom corners of the steamer. Or, thread the four optional 4" adjustable legs into
the threaded holes on the bottom corners of the steamer.
Summary of Contents for Premier PS-3E
Page 4: ...4 1 0 SERVICE CONNECTIONS ...
Page 28: ...28 FIGURE 3 ...
Page 34: ...34 ...
Page 35: ...35 ...
Page 36: ...36 ...