WASH-1 USER GUIDE
24
When the equilibrium temperature after restart is roughly 127-128
O
F, only 2-3 degrees below the alarm
temperature,
drain the boil chamber
(following instructions in the
Solvent Drain
subsection of the
Drain
Procedure
section below) and safely discard the wax-saturated solvent, then
refill the boil chamber
with
fresh solvent. Restart the heaters and proceed with washing.