Setting the Mode of Operation
1. Removing the body (=> page 41/42).
2. Setting the coding switches.
Switch 10 (0) at off:
Operation with AC power
Switch 10 (0) at on:
Operation with DC power
The Digital / Delta mode of operation
is always recognized automatically.
Setting the Digital Address
1. Removing the body (=> page 41/42).
2. Set the desired address with swit-
ches 1 to 8.
Example: 21 is the desired address.
Switches 1, 4 and 7 at on.
Switches 2, 3, 5, 6 and 8 at off.
Important: Switch 9 must always be
set at off.
Setting the Running
Characteristics
1. Removing the body (=> page 41/42).
2. The respective running characteris-
tics can be changed by changing
the setting on the potentiometers.
These potentiometers have a stop
at the end positions. When you
encounter resistance when turning
the “pots”, do not try to turn them
further with force.
P1: Acceleration / braking delay
(together)
Left stop: minimum delay
Right stop: maximum delay
P2: Maximum speed
Left stop:
lowest maximum speed
Right stop:
highest maximum speed
2
15
Operation
P2
P1