Reset the i-Que back to factory default
Unplug the batteries and place aside
Find the Black And Yellow cable
Using a reset wire (small piece of wire or paper clip)
short the two wires of the black and yellow cable together
(place the wire from the one hole on the connector to
the one next to it, thus making a loop)
With the reset wire in place reinstall the batteries.
The LED should go RED then Green, You should hear the lock relock.
Remove the reset wire and reassemble the batteries and cover on to
the housing assembly.
The lock is now reset. You are now at the point of set up.
Install the
LOCK ID
and
GGM
code. (See Page 2)
Yellow and Black
Red and Black
Secretaries Button, (Orange and Black)
This can be wired to a Momentary
N
ormally
O
pen (NO) switch When pressed, lock will
open for the set amount of time.
(button not included)
Reset / Key Switch Black And Yellow
(factory Installed option)
This option will monitor if a key is used
to open the lock.
For Resetting the i-Que see below
Motor cable
Red and Gray lines to the
motor connector
Power RED (+) and Black (-)
6 Volts DC. Connects to the supplied battery pack
Panic Alarm (Green and Black)
hard wired to an alarm device
When
function 38
is enabled (see page 8) on
and a user enters 911
*
it will close the
contact setting off the alarm.
Blue and Black
Request to Exit switch.
(Factory installed option)
Switch installed in the inside rose
will record all opening in the
audit trail
Cylindrical model shown (IQ1K).
Please note: The Mortise (IQ2K) Tubular (IQ3K)
and Exit device interface (IQ7K) will not have the motor leads.
These leads will be connected inside the front trim by the factory.
Connection Diagram
Page 14
Cable Gard
Prox Antenna
The lock is now reset. You are ready to initialize the lock.
Install the
LOCK ID
and
GGM
code. (See Page 2.)