Page 5
Function 11: Set Access Level
Min. Group Number 03
Access can be denied to Users in Groups lower then the Group number entered.
This function
cannot
deny access to Groups 03 (
Master
), 02 (
Grand Master
), or 01(
Great Grand Master
).
To allow all Groups access the Group level setting must be set to “99”.
Function 18: Define Open Time
Min. Group Number 03
This function will set the time delay the lock will stay unlocked after a valid user code has been entered.
The time delay can be set from 1 to 9 seconds. (
Default setting is 3 seconds.
)
Function 33: Multiple Code Entry
Min. Group Number 03
For higher security the lock can be set to require two User codes be entered before access is granted.
For even higher security it can be required for one of the Users to be in a Manager Group.
One User code required - Default
Two User codes required
Two User codes one must be a Manager
Three Code Entry - Two User codes plus a Manager
PROGRAM
INSTRUCTION
UID #
PROX
33
✳
3
✳
✳
PROGRAM
INSTRUCTION
UID #
PROX
33
✳
2
✳
✳
PROGRAM
INSTRUCTION
UID #
PROX
33
✳
1
✳
✳
PROGRAM
INSTRUCTION
UID #
PROX
33
✳
0
✳
✳
PROGRAM
INSTRUCTION
UID #
PROX
18
✳
Single Digit, 1 - 9 seconds
✳
✳
PROGRAM
INSTRUCTION
UID #
PROX
11
✳
Group Level
✳
✳