IMPORTANT  KEYS:

 

TERMINATOR  KEY 

( ):

 

Acts like the 

“Enter” key on a computer, and is used to confirm entries on the keypad. 

PROGRAMMING KEY 

(#):

 

After a valid Master Code is entered, this key is depressed to enter the programming mode. 

NOTE: At the end of any programming series, replace the last 

 

with a # to return to function number input.

 

This allows the programmer to perform multiple functions without having to re-enter the Master Code for each function.

 

LED  INDICATOR:

 

LED INDICATING 

GREEN (NORMAL MODE):

 

1. 

Denotes lock enabled to open. Will flash green after valid entry and terminator key (

 

LED INDICATING 

RED (NORMAL MODE):

 

1. 

Denotes a wrong code entry. 

2. 

Three consecutive wrong entries will disable keypad for 20 seconds. If another wrong code is entered, the keypad is 
disabled for 40 seconds. This is indicated by a solid red light. 

LED INDICATING 

RED (PROGRAMMING MODE):

 

1. 

Denotes incorrect entry and vacates programming mode. 

2. 

Programming mode vacated if no key entry within 5 seconds. 

CREATE MASTER CODE

 

This code is required to perform all programming functions. The number of digits used for the User ID and PIN of each additional 
user must be the same as the Master Code. 

 

 

Enter  9991234

 

 

 

 

 

 

(User ID)

 

#

 

 

 

 

(PIN)

 

#

 

 User ID and PIN followed by 

 will open the lock. 

GROUPS

 

ALL USERS MUST BE ASSIGNED TO A GROUP. 

Users in the same group will have the same access rights. 

Each group is assigned a 2 digit group number from 02 to 99. 
The Master Code is automatically assigned to group 01, and has full programming rights. 

GROUPS 02-08: 

Management groups with 24/7 access. 

GROUP 09: 

Group that allows the lock to be placed in passage mode when the code is entered. The lockset will re-lock when code is 

entered again or at midnight of that day. 

GROUPS 10-99: 

No programming rights. They may, however, change their own PIN. (See 

“Change User PIN” on page 2) 

TO ADD USERS

 

Enter Master Code (User ID and PIN), the 

key, (01), the   key, the User ID you wish to add, the   key, the 2 digit group number,  the 

 key, the new PIN, and the   key twice. 

 

ADD USER CODE

 

 

Enter MASTER CODE

 

#

 

01

 

 

 

 

 

 

(User ID)

 

 

 

10

 

 

 

 

 

 

(PIN)

 

 

 

 

 

User ID and PIN followed by ( ) will open the lock.

 

TO DELETE USERS

 

Enter Master Code (User ID and PIN), the 

key, (01), the   key, the User ID you wish to delete, the   key, (0), and the   key twice. 

 

DELETE USER CODE

 

 

Enter MASTER CODE

 

#

 

01

 

 

 

 

 

 

(User ID to be Deleted)

 

 

 

0

 

 

 

 

 

Summary of Contents for i-Qwik LITE Series

Page 1: ...PROGRAMMING GUIDE MARKS USA 365Bayview Ave Amityville NY 11701 631 225 5400 1 800 526 0233 Fax 631 225 6136 ...

Page 2: ... Groups Page 1 To Add Users Page 1 To Delete Users Page 1 Pin Only Entry Page 2 Change User Pin Page 2 Define Open Time Page 2 Lock Audio Page 2 Terminator On Off Page 2 Manual Passage Mode Page 3 Temporary User Schedule Page 3 Set Time Page 3 Set Date Page 3 Double Code Entry Page 3 Privacy Mode Secretary Mode Page 4 Disable Enable Three Strike Lockout Page 4 Clear Memory Page 4 Battery Check Sta...

Page 3: ...ithin 5 seconds CREATE MASTER CODE This code is required to perform all programming functions The number of digits used for the User ID and PIN of each additional usermustbethesameastheMasterCode Enter 9991234 UserID PIN UserIDandPINfollowedby willopenthelock GROUPS ALL USERS MUSTBE ASSIGNED TO A GROUP Users in the same group will have the same access rights Eachgroupisassigneda2digitgroupnumberfr...

Page 4: ...illstayunlockedafteravalidUsercodehasbeenentered Theopentimecanbesetfrom1to9seconds Defaultsettingis3seconds Enter MASTER CODE 18 SingleDigit1 9Seconds LOCK AUDIO Whentheaudioissetto ON thelockwillbeepwitheachkeypressed Onbydefault AUDIO OFF Enter MASTER CODE 34 0 AUDIO ON Enter MASTER CODE 34 1 TERMINATOR ON OFF This function will switch the Terminator On or Off Selecting off automatically sets l...

Page 5: ...ned or access repeats annually This function requires setting the date in the lockset see Set Date below Enter MASTER CODE 06 UserID MMDD Start Date MMDD EndDate SETTIME Thisfunctionwillsetthetime HHMM Timeissetin24hourformat Example 3 30pm 1530 Enter MASTER CODE 12 HHMM Daylightsavingstimeisenabledbydefault Todisabledaylightsavingsadda 0 zero attheendofthetimeentry Example 3 30pm 15300 SET DATE T...

Page 6: ...e to 40 seconds maximum Disabling this feature allows an unlimited number of incorrect codes to be entered without a lockout DISABLE Enter MASTER CODE 40 0 ENABLE Enter MASTER CODE 40 1 CLEAR MEMORY If it becomes necessary to reset the memory of the i Qwik LITE there are two options other than the Full Reset option DELETEALLUSERS SCHEDULES Enter MASTER CODE 16 16 0 DELETE ONLY SCHEDULES Enter MAST...

Page 7: ...rve determines the power settings for thetwostagesofbatterywarningsandtheFailSecuresettings Alithiumbatterydiffersfromanalkalinebatteryinthelifecycleofthebatterycell Alithiumbatteryhasavery sharp drop off voltage going from fully charged to a dead cell quickly This makes monitoring the voltage settings impossible TWO STAGE LOW BATTERY WARNING The i Qwik LITE has a two stage low battery warning The...

Page 8: ... product line templatesandmanuals visitourwebsite www marksusa com For i Qwik i Que Tech Support Call Toll Free 800 526 0233 In N Y 631 225 5400 Fax 631 225 6136 LIVE TECH SUPPORT 8am to 8pm EST Mon Fri Email techsupport marksusa com IP101 IQWIKLITE 03 09 2009 MARKSUSA Distributed by ...

Reviews: