MASTER UID # PROX
01
UID to be
Deleted
0
UID
PROX
UID
#
PROX
3
FUNCTION 01: Cont’d
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Min. Group Number: Master 03
To Delete Users:
Enter MASTER CODE (UID #, then PROX), FUNCTION NUMBER (01), the key, the Users UID you want to delete, the key,
the 0 key in place of the GROUP NO., the key twice.
NOTE: GROUP NUMBERS ARE NOT USED TO ACCESS THE LOCK
Users Access the Lock:
Enter User’s UID, then the key, then PROX. The lock will open!
Users Entry to Programming Mode:
Enter User’s UID, then the # key, then PROX.
PROX Only Mode (for Access PIN Only)
Master UID # PROX
32
0
UID & PROX Required - Default
Master UID # PROX
32
1
SECTION 2; LOCK CONFIGURATION
FUNCTION 32: PROX Only Entry
. . . . . . . . . . . . . . . . . . . . . . .
Min. Group Number: Grand Master 02
The PROX Only mode allows access by presenting only the PROX card.
NOTE: PROGRAM MODE REQUIRES THAT UID BE ENTERED
UID # PROX
08
NEW
NEW
FUNCTION 08: Change User PROX
. . . . . . . . . . . . . . . . . . . . .
Min. Group Number: Groups 01 - 99
This function gives users the ability to change their PROX.
(USER MUST KNOW THEIR UID AND HAVE THEIR PROX CARD)
Marks USA • www.marksusa.com • 631-225-5400 • 800-526-0233 • Fax: 631-225-6136 •
© 2009, Marks USA