Rutland FM1803-2
Installation & Operation
Document No: SM-146 Issue G 01.11.20
Marlec Engineering Co Ltd
9
MOUNTING TOWER
The Rutland 1803-2 is designed to fit inside a round tube with an internal diameter of 81mm.
A suitable mounting pole can be erected using 80mm (3“) galvanised (medium) tube to BS1387
a minimum height of 6.5m, 10m or greater is recommended. The tube must be supported by a
minimum of 2 sets of four guy lines.
The attachment points for the guy lines to the tower should be securely fixed to the tower.
•
All items should be galvanised or stainless steel for protection against corrosion.
•
Where guy lines are looped, the loop must incorporate a thimble and be fitted with a
minimum of three rope grips.
•
All ground fixings must be made suitable according to the ground conditions.
Pivot type towers are recommended as these allow for easier installation and lowering for
access to the wind generator for maintenance. A form of pivoting tower is suggested in Fig 2.
Non-guyed lattice and pole type pivoting towers are available, for further details contact the
dealer or manufacturer.
Fig 2. Typical Tower