Rutland Furlmatic 910-4 Windcharger Installation & Operation
Doc No: SM-138 Iss. A 29.01.13
10
Marlec Eng Co Ltd
Furlmatic Tail Assembly (Fig. 5)
Fit the tail fin on to the
hinge assembly using the screws and washers already
present:-
Do not remove the silicone protectors
NB. The tail fin is set at an angle of 15° from vertical. This is vital to the furling
mechanism. The mounting pole also needs to be perfectly vertical for furling to
take.
Fig 5
Rutland Furlmatic 910-4 Windcharger Installation & Operation
Doc No: SM-138 Iss. A 29.01.13
11
Marlec Eng Co Ltd
Tower Preparation (Fig. 6)
Having selected a suitable pole from the guidelines.
The post adaptor fitted to the FM910-4 is designed to fit inside a standard
41mm (1 ") internal diameter tube. The adaptor is provided with a flat on one
side to clear the weld seam on seamed pipe.
Mark and centre-punch two positions diametrically opposite, at 90° to the pipe
seam if necessary, 20mm (
NOTE: Use metric measurements for this operation)
from the top of the tube.
Drill two holes 10.5mm (
NOTE: Use metric measurements for this operation)
in
diameter on centre-punch positions.
Note: When using the Rutland Land Tower Kit, items 2 and 3 can be ignored as
the unit is pre-drilled.
Fig 6