background image

The “R” Series heaters are designed for recessed installation in
standard  2  x  4    (50mm  X  100mm)  or  larger  stud  walls  with  the
back box mounted as shown in either Fig. 1, or Fig. 2.

NOTE:

Heater should be controlled by either built-in thermostat or

remote wall thermostat. Models with “T2” suffix are equipped with
built-in thermostat.

This heater may be wired with standard building wiring (rated 
minimum 60° C).  Refer to Table 2 (Page 3) for appropriate wire
size for the heater to be used.

TO INSTALL BACK BOX (Model RBB)

IN NEW CONSTRUCTION - WALL STUDS 16” OC.

(REFER TO FIG. 1)

1.

Locate back box  (model RBB) and back box support 
brackets (2).  Back box must be installed with mounting rails
to the top (see Fig. 1B).

2.

Install  back  box  support  brackets  with  foot  tabs  directed
towards the center of the back box as shown in Fig. 1A and
1B.  It may be necessary to bend up slightly the tab on the
back box support bracket to allow insertion under the mount-
ing lances on the bottom of the back box.

3.

Determine which knockout in back box will be used for field
wiring  and  remove  (see  back  box  drawing  pg.1).    Install
strain relief (field supplied). See warning No. 13.

4.

Fish field wiring through strain relief leaving 6” of wire inside
box.

5.

Insert back box assembly into wall, aligning rear of back box
with back side of studs (see Fig. 1C).  The back box support
brackets should be resting on the sole plate of the stud wall
to insure proper spacing and leveling (see Fig. 1B).

6.

Using four (4) wood screws or drywall screws or four (4) nails
(field  supplied),  secure  back  box  to  studs  (see  Fig.  1B).
Back  box  support  brackets  can  now  be  removed.    If  not
removed, secure to sole plate.

TO INSTALL BACK BOX IN NEW CONSTRUCTION -

WALL STUDS SPACING GREATER THAN 16” OC.

(REFER TO FIG. 2)

NOTE:  

Fig. 2 depicts the back box installed with the left side 

adjoining stud.  For a box with the right side adjoining a stud, 
reverse the directions shown below.
1.

Locate back box and back box support brackets (2).  Back box
must be installed with mounting rails to the top (see Fig. 2B)

2.

Determine  which  side  of  the  back  box  will  adjoin  stud  and
insert  back  box  support  bracket  on  that  side  with  foot  tab
directed towards center of back box.  On the side of the back
box that will not adjoin stud, install back box support bracket
on  that  side  with  foot  tab  directed  towards  end  of  box  and
secure to box with 3/8” long sheet metal screw (provided).

3.

Determine which knockout in back box will be used for field
wiring  and  remove  (see  back  box  drawing  pg.  1).    Install
strain relief (field supplied).

4.

Fish field wiring through strain relief leaving 6” of wire inside
box.

5.

Insert back box assembly into wall, aligning rear of back box
with back side of stud (see Fig. 2C).  The back box support
brackets should be resting on the sole plate of the stud wall
to insure proper spacing and leveling (see Fig. 2B).

6.

Use two (2) wood screws or drywall screws or two (2) nails
(field supplied) to secure the side of the back box that adjoins
a stud.  Use one (1) wood screw or drywall screw or one (1)
nail  (field  supplied)  to  secure  the  foot  tab  of  the  back  box
support bracket (that is on the end opposite the stud) to the
sole plate (see Fig. 2B).

TO INSTALL BACK BOX  IN 
EXISTING CONSTRUCTION

1.

Locate wall studs to be sure that entire cut-out can be made
between studs.  At least one side of the cut-out must be flush
with side of the stud.  Bottom of cut-out must be 4” above 
finished floor minimum.  Make a cut-out in wall 14-1/2” wide
X 6-3/4” high (368mm X 171mm) (see Fig. 3). 

2.

Determine which knockout in back box will be used for field
wiring  and  remove  (see  back  box  drawing,  pg.1).    Install
strain relief (field supplied).

3.

Fish field wiring through strain relief leaving 6” of wire inside
box.

4.

Insert  back  box  into  cut-out.    Rear  of  back  box  should  be
flush with back of stud wall.

5.

Using four (4) wood screws or drywall screws (field supplied)
or  four  (4)  nails  (field  supplied),  secure  back  box  to  studs
(see Fig. 1B).  If wall studs are greater than 16”oc., use only
2 fasteners and on the opposite end of the back box drive a
1”  sheet  metal  screw  (provided)  through  hole  in  end  cap.
This  will  draw  the  back  box  tight  with  drywall  when  grille  is
installed.  (See Fig. 4.)

TO INSTALL THERMOSTAT ASSEMBLY (RT2 only)

NOTE:  

Thermostat assembly should not be installed until after

the drywall phase of construction is complete. Dust from drywall
installation and joint compound can be harmful if it gets inside
thermostat assembly components. 

1.

The thermostat must be installed in right end of the heater.

2.

Position thermostat above slot in right end of back box.  
Push tab on thermostat bracket through slot in top, right 
end of back box until the bracket locks in place.  See Fig. 5.

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BACK BOX (FRONT VIEW)

NAIL OR SCREW

4 PLACES

BACK BOX

SUPPORT BKTS.

SOLE PLATE

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STUD

STUD

MOUNTING RAILS

M

 

 

 

 

 

 

 

 

 

 

BACK BOX

TOP VIEW

INSERT FAN DECK

THIS SIDE

STUD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1A

Fig. 1B

Fig. 1C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BACK BOX (FRONT VIEW)

NAIL OR SCREW

BACK BOX

SUPPORT BKTS.

SOLE PLATE

B

 

 

 

 

 

NAIL OR SCREW

STUD

STUD

 

MOUNTING RAILS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BACK BOX

TOP VIEW

INSERT FAN DECK

THIS SIDE

STUD

 

 

 

 

Figure 2A

Fig. 2B

Fig. 2C

 

 

 

 

 

 

 

 

 

Figure 3

The “IF” models do not include a backbox.  The Backbox is
ordered separately.  In the parts bag for “IF” models, there is a
white label that indicates multiple wattage and must be place in
the backbox on the bottom right-hand side.  When making
wattage changes, the installer must circle the wattage on the
white label before installing the heat deck.

NOTE TO INSTALLER

Summary of Contents for R1500

Page 1: ... air intakes or exhaust in any manner Keep combustible materials such as crates drapes etc away from heater Do not install behind doors furniture towels or boxes 7 A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are used or stored 8 Use this heater only as described in this manual Any other use not recommended by the manufacture...

Page 2: ...5 Insert back box assembly into wall aligning rear of back box with back side of stud see Fig 2C The back box support brackets should be resting on the sole plate of the stud wall to insure proper spacing and leveling see Fig 2B 6 Use two 2 wood screws or drywall screws or two 2 nails field supplied to secure the side of the back box that adjoins a stud Use one 1 wood screw or drywall screw or one...

Page 3: ...r at main fuse or circuit breaker distribution panel 3 Figure 6 TABLE 2 TOTAL AMPS 0 thru 12 12 1 thru 16 16 1 thru 24 WIRE SIZE COPPER 14 12 10 CIRCUIT BREAKER OR FUSE SIZE 15 Amps 20 Amps 30 Amps TO CHANGE WATTAGE OUTPUT The chart shows the wattages available by model Each heater is factory wired for its maximum wattage The last two columns in the chart refer to the jumpers on the CLIP n Fit Boa...

Page 4: ...nearest authorized service center contact Marley Engineered Products in Bennettsville SC at 1 800 642 4328 Merchandise returned to the factory must be accompanied by a return authorization and service identification tag both available from Marley Engineered Products When requesting return authorization include all catalog numbers shown on the products 09 11 MODEL NO R1500T2 DATE CODE 0599 FAN FORC...

Page 5: ...a prevenir un posible incendio Mantenga los materiales com bustibles tales como cajas de madera cortinas etc alejados del calentador No instale detrás de puertas muebles toallas o cajas 7 Un calentador tiene adentro piezas calientes y productoras de arcos eléctricos o de chispas No use en áreas donde estén alma cenados gasolina pintura o líquidos inflamables 8 Use este calentador sólo de la manera...

Page 6: ...gurar la aleta de pie de la ménsula de soporte de la caja posterior que está en el extremo opuesto del montante a la placa de base INSTALACION DE LA CAJA POSTERIOR EN UNA CONSTRUCCION EXISTENTE 1 Ubique los montantes de pared para asegurar que se pueda efec tuar todo el corte entre los montantes Uno de los lados del corte por lo menos debe estar al ras con el lado del montante El fondo del corte d...

Page 7: ...LE 15 Amp 20 Amp 30 Amp Figura 5 BACK BOX END CAP HOLE TOP OF BACK BOX FLANGE ON FAN DECK MOUNTING RAIL Figura 7 TABLA 1 MODELO R1500 R1500T2 R2004 R2004T2 R2404 R2404T2 VOLTIOS 120 240 208 240 208 VATIOS AMP 1500W 12 5A 2000W 8 3A 1500W 7 2A 2400W 10 0A 1800W 8 7A VATIOS AMP 1125W 9 4A 1500W 6 3A 1125W 5 4A 1800W 7 5A 1350W 6 5A VATIOS AMP 750W 6 3A 1000W 4 2A 750W 3 6A 1200W 5 0A 900W 4 3A VATIO...

Page 8: ...ión de devolución y una etiqueta de identificación de servicio ambas disponibles de la ubicación indicada Incluya todos los números de catálogo mostrados en el producto al requerir autorización de devolución FRONT VIEW SIDE VIEW BOTTOM VIEW 09 11 NO DE MODELO R1500T2CODIGO DE FECHA 0597 FAN FORCED WALL HEATER CALENTADOR MURAL DE TIRO FORZADO POR VENTILADOR 120 1500 1125 750 375 12 5 9 4 6 3 3 1 VO...

Page 9: ...me les boîtes les cageots les rideaux etc éloignés du radiateur Ne pas installer le radiateur derrière des portes des meubles des serviettes ou des boîtes 7 Un radiateur contient des pièces chaudes et produisant des arcs électriques ou des étincelles Ne pas l utiliser dans des zones d utilisation ou de remisage d essence de peinture ou de liquides inflammables 8 Utiliser ce radiateur uniquement se...

Page 10: ...de semelle voir la figure 2B INSTALLATION DU BOÎTIER ARRIÈRE DANS UNE CONSTRUCTION EXISTANTE 1 Identifier l emplacement des poutres murales pour s assurer de pou voir faire toute la découpe entre les poutres Au moins un des côtés de la découpe doit être au ras d une poutre Le bas de la découpe doit être au moins 101 mm au dessus du sol fini Faire une découpe dans le mur de 368 mm de large et de 17...

Page 11: ...ableau montre les puissances disponibles par modèle Chaque radia teur est câblé en usine pour sa puissance maximum Les nombres dans le tableau se rapportent aux bornes DU CIRCUIT DE CONTRÔLE DE PUISSANCE Pour changer la puissance déplacer le fil d alimentation ou le cavalier comme indiqué dans le tableau ci dessous Figure 5 TOP OF BACK BOX FLANGE ON FAN DECK MOUNTING RAIL Figure 7 TABLEAU 1 MODÈLE...

Page 12: ...ntacter Marley Engineered Products à Bennettsville Caroline du Sud États Unis d Amérique au 1 800 642 4328 La marchandise renvoyée en usine doit être accompagnée d étiquettes d identification d autorisation de renvoi et de service disponibles chez Marley Engineered Products Lors de la demande d autorisation de renvoi inclure tous les numéros de catalogue apparaissant sur les produits FRONT VIEW SI...

Reviews: