MGT 240M–1200M NXT2 3” TWIN ALTERNATING
INSTALLATION
19
MASTER PROGRAMMING MODE FLOW CHART
NOTE:
Depending on current option settings, some displays cannot be viewed or set.
Master Programming Mode:
1. Press and hold the Left and Down buttons simultaneously for 3
seconds to enter Master Programming mode.
2. To navigate, press the Extra Cycle button to advance to the next
value. Press the Left button to retreat to the previous value.
3. Where applicable, use the Down and Up buttons to adjust a
value as desired. When entering data into text fields (such as
Assistance Name) or numerical fields (such as Hardness),
press the Extra Cycle button to advance to the next character/
digit and press the Left button to retreat to the previous
character/digit. Proceed through all available characters/digits
to advance to the next value.
4. To reset/clear a value (such as Assistance Name), while on the
value, press and hold the Down and Up buttons simultaneously
for 5 seconds.
5. To exit master programming mode, progress through all avail
able values or after 5 minutes of inactivity the timer will exit
automatically. To exit master programming without saving
changes, press the Left button until you return to the service
screen.
6. Depending on the current controller programming, certain
values may not be able to be viewed or set.
7. The timer will display local information, not system information.
8. In the event of a regeneration occurring while displaying master
programming, the regeneration step and time remaining will be
displayed. When regeneration has been completed, the display
will return to the main screen.
9. If any values are changed, make sure Push Settings is set to
ON so the values are pushed to the other unit(s).
Example:
On: View settings without the ability to alter settings.
Off: User has ability to alter settings.
OFF
ON
SETTINGS REVIEW
Example:
English, Francais, Duetsch, Italiano,
Espanol, Nederlandse, Portugues
ENGLISH
FRANCAIS
PORTUGUES
LANGUAGE
Example:
12 characters maximum.
ASSISTANCE NAME 1
Example:
12 characters maximum.
ASSISTANCE NAME 2
Example:
14 characters maximum.
ASSISTANCE PHONE
Example:
4, 5, 6, 7, 8, 9, 14
SYSTEM 5
SYSTEM 6
SYSTEM 4
SYSTEM
Example:
2510, 2750, 2815, 2900, 3150, 3900
2850
2900
2815
VALVE
Example:
Upflow
Downflow
Filter
DOWNFLOW
FILTER
UPFLOW
REGEN. FLOW
Example:
Softener Meter Delayed
Softener Meter Immediate
Time Clock
Day of the Week.
SOFTENER METER IMM
TIME CLOCK
SOFTENER METER DEL
REGEN. TYPE
Example:
Metric
US
US
METRIC
UNITS
Example:
Range: 0-9,999,999 grains
0023828
CAPACITY - GRAINS
Example:
Range: 0-199 GPG
Example:
Fixed Volume
Weekly Reserve
Variable Reserve
Fixed %
WEEKLY RESERVE
VARIABLE RESERVE
FIXED VOLUME
RESERVE
Example:
Off, Immediate, Delayed
OFF
IMMEDIATE
DELAYED
REMOTE REGENERATION
Example:
Range:
1-90 seconds (Service)
60-300 seconds (Standby)
1 S
REMOTE SIGNAL DURATION
Example:
Range: Off - 99 Days
10 D
DAY OVERRIDE/TIME-DRIVEN
Example:
Range: 0 - 23 Hours 59 Minutes.
02:OOHR
REGEN. TIME
025
HARDNESS - GPG
Example:
2, 3, 4, 5, 6, 7, 8
2
8
3
NUMBER OF TANKS
Example:
Trip Points only available/visible when
System Type 14 is selected.
0001
TRIP POINT #1 - GPM
1 S
TRIP POINT #1 - SERVICE DURATION
60 S
TRIP POINT #1 - STANDBY DURATION
Example:
Range: 1-90 seconds
Example:
Range: 60-300 seconds