background image

Q

UICK

-R

EAD

  

 -   3

TRANSDUCERS AND

MEASUREMENT TRANSMISSIONS

BORE GAUGES LINE

FORKS AND RING GAUGES

BENCH GAUGES

INDICA

TORS AND ELECTRONIC DISPLA

Y UNITS

INTERF

ACE BO

XES

FOR DA

TA

  ACQUISITION

SOF

TWARES

MICROCOLUMN VERSION

This version incorporates half-bridge technology (HBT) and allows to connect TESTAR /MARPOSS standard
sensors with half-bridge transducer ranging from ± 0,25 mm (.010”) to ± 5 mm (.200”).
Two versions are available  :
• For connection of one sensor to carry out one static measurement .
• For connection of one or two sensors to carry out one static or dynamic measurement [Hold, Max, min, Max-

min, (Max- min)/2, (Max+min)/2]. To connect two sensors the specific Y-cable is needed.

P

OWER

 

SUPPLY

7 - 7,5 Vdc ± 5% (300 mA)

P

ROTECTION

 

LEVEL

 (CEI/IEC 529 - DIN VDE 0470-1)

IP50

A

CCURACY

± (1% reading value + resolution)

M

EASUREMENT

 

THERMAL

 

DRIFT

0,1 µm/°C for range up to ± 1 mm (.04000”);
0,2 µm/°C for range ± 2,5 mm (.10000”) and ± 5 mm (.20000”)

O

UTPUT

RS232

W

ORKING

 

TEMPERATURE

0 ÷ 50 °C

S

TORAGE

 

TEMPERATURE

- 40 ÷ 50 °C

G

ENERAL SPECIFICATIONS

(*) HBT standard TESTAR/MARPOSS. For third parties transducer compatibility please contact the nearest MARPOSS office.

A

VAILABLE

 

SCALES

auto; 0,010 mm (.00050”); 0,020 mm  (.00100”);
0,050 mm (.00250”); 0,100 mm (.00500”); 0,250 mm (.01000”);
0,500 mm (.02500”); 1,000 mm (.05000”); 2,5 mm (.10000”);
5 mm (.25000”); 10 mm (.50000”)

R

ESOLUTION

1/10 of the programmed scale,
from 0,001 mm (.00005”) to 1,000 mm (.05000”)

T

YPE

21 three colour LEDs (green, yellow, red)

A

NALOG DISPLAY

R

ESOLUTION

0,0001/0,001 mm (.00001”/.00005”) for measuring range up
to  ± 1 mm (.04000”); 0,001 mm (.00005”) for range
± 2,5 (.10000”) and ± 5 mm (.20000”)

T

YPE

8 alphanumeric digits

M

EASUREMENT

 

MULTIPLYING

 

COEFFICIENT

-2 to +2 with 0,01 step

D

IGITAL DISPLAY

1 or 2 half-bridge (*) with Lumberg SV50/6 connector

M

ANAGEABLE TRANSDUCER

      

D

ESCRIPTION

O

RDER

 C

ODE

M

ICROCOLUMN

  V

ERSION

 

FOR

 

ONE

 

SENSOR

  (

ONE

 

STATIC

 

MEASUREMENT

)

0E01991613

M

ICROCOLUMN

 V

ERSION

 

FOR

 

ONE

 

OR

 

TWO

 

SENSORS

 (

ONE

 

STATIC

 

OR

 

DYNAMIC

 

MEASUREMENT

)

0E01991612

Y-

CABLE

 

FOR

 

CONNECTION

 

OF

 

TWO

 

SENSORS

6735532001

 N

N

N

N

N

OTE

OTE

OTE

OTE

OTE

: : 

: : One  User manual is supplied with each Quick Read.

 FOR CONNECTION OF ONE SENSOR

ONE STATIC MEASUREMENT

FOR CONNECTION OF ONE OR TWO SENSORS

ONE STATIC OR DYNAMIC MEASUREMENT