THERAPY PUMP(S)
Startup procedure for all models
1. Place spa on a hard, flat, level surface. Make sure
the power supply is off.
2. Make sure the suction guard(s) in the footwell are in
place and undamaged.
3. Open the equipment door. Tighten all disconnects and
open all shut-off valves.
NOTE:
Keep the drain valve closed at all times except
when draining the spa (do not rely on the cap to stop the flow of water). Not
doing so could result in damage to the drain valve due to freezing water.
4. Install filter cartridges. (See
INSTALLATION
INSTRUCTIONS
, Filter Cartridges.)
5. Fill the spa with water to two-thirds of the way up the Vortex skimmer
openings. The use of a
Fill Filter
is recommended, especially in areas with
high mineral content in the water.
6. Turn the power on.
WARNING:
Spa must be completely filled with water before turning on power.
7. Your spa is now in “pump priming” mode and a “RUN PMPS PURG AIR”
message displays in the LCD window of the control panel. While in this
mode the spa appears idle, which lasts approximately four to five minutes if
not exited manually. To exit manually, press the TEMP+/- pad.
8. Allow the spa to circulate on high-speed (see SPA CONTROL OPERA-
TION) for four to five minutes to discharge air from the plumbing system.
Do not expect hot water immediately from the jets; the heater will take
several hours to heat the water.
9. At this time the spa should have water flowing from the jets. If the pump
has not primed and the water is not flowing from the jets after two min-
utes TURN OFF POWER TO THE SPA and vent air from the pumps by
slightly opening the pump unions located behind the equipment door.
After turning the power on again, the spa initiates a new priming mode.
Repeat steps above.
10. The system requires approximately two minutes of water flow to de-
termine the water temperature. After two minutes of water flow, the
temperature is displayed as actual water temperature. After you have
manually exited the priming mode (or allowed the spa to automatically exit)
the LCD window momentarily displays 100°F (38°C) and then the display
switches to - - °F.
11. The factory default setting for water temperature is 100°F (38°C). Use
the TEMP pad on the control panel to set the water temperature to the
desired level. (See SPA CONTROL OPERATION.) It takes up to 24 hours
to heat the water to desired temperature depending on the water tem-
perature and voltage of your spa.
12. If water is not coming out of the jets, check to make sure the adjustable
jets are open. Simply turn the jet face to open or close the jets.
Test the water for the proper chemical balance and adjust as neces-
sary. SpaCare products are recommended. (See
WATER TREATMENT
.)
PROPER CHEMICAL BALANCE IS IMPORTANT
for your safety and the
longevity of your spa.
STARTING YOUR SPA
Vent air by slightly
opening pump unions.
13
Summary of Contents for V65L
Page 16: ...THE V65L ZONES ZONE 1A N N N ZONE 1B N N N N N N ZONE 1C 16...
Page 18: ...THE V77L 1 PUMP ZONES ZONE 1A N N N ZONE 1B N N N N N N ZONE 1C 18...
Page 19: ...THE V77L 2 PUMP ZONES ZONE 1A N N N ZONE 1B N N N N N N ZONE 2 19...
Page 21: ...THE V84 1 PUMP ZONES ZONE 1A ZONE 1B ZONE 1C 21...
Page 22: ...THE V84 2 PUMP ZONES ZONE 2A ZONE 2B 22...
Page 24: ...THE V84L 1 PUMP ZONES ZONE 1A ZONE 1B THE V84L 2 PUMP ZONES ZONE 2A ZONE 2B 24...