background image

Teaching a New Token

The following procedure must be followed in order to teach
a new token into channel 1.

NOTE:- Rotary data switch position “E” is used to
program tight window token limits and ‘F’ standard

window token limits.

1.

Switch 

OFF

 the power to the validator.

2.

Set the 4 way 

DIL

 teach switches 2, 3 & 4 to 

ON,

ON

 & 

OFF

 (channel 1) or OFF, ON & ON for

(channel 0)

3.

Set rotary data switch to position “F” standard     

window limit.

4.

Switch 

ON

 the power to the product.

(The 

LED

 will start flashing).

5.

Insert 10 to 20 (minimum 10) of the desired

tokens through the validator.

6.

Return the 4 way 

DIL

 switches 2, 3 & 4 to

Normal Operation settings.

(

LED

 will stop flashing and stay 

ON

 to indicate

success).

If the 

LED

 continues to flash 

OFF

 a number of

times this indicates a failure to teach the new
token. See 

LED

 Assistance Codes table for help

and then restart procedure again.

7.

Token is now programmed and ready to use.

(New token information has been stored in coin
channel “1” which is rotary switch position “1”).

Any previous taught token information in this
channel will be overwritten).

NOTE:- If token self teach is successful but token
taught is rejected i.e. gives 3 flashes of the 

LED,

 check

that channel “1” is enabled.
To enable the new token set the rotary data switch to

position “1” then refer to  enabling coin or tokens

configuration procedure).

Product Configuration

-

F

Auto configuration

-

D

Parallel output

ON

OFF

OFF

-

C

Binary coded output

Selecting Machine Interface Types

-

-

-

OFF

-

Set the alarm 

OFF

-

-

-

ON

-

Set the alarm 

ON

ON

OFF

OFF

-

0 - 7

Change overflow default exit route

ON

OFF

ON

-

E

Fraud Defence teach channel 0

OFF

ON

ON

-

s

E or F

Self teach a token for channel 1

ON

ON

OFF 

-

s

E or F

Self teach a token for channel 0

OFF

ON

ON

-

0 - D

Token group for channel 1

ON

ON

OFF

-

0 - D

Token group for channel 0

OFF

OFF

ON

-

0 - F

Enable a coin or token channel

OFF

ON

OFF

-

0 - F

Inhibit a coin or token channel

SW4

SW3

SW2

SW1

2

3

4

ON

1

2

3

4

ON

1

Channel
Position

Product Configuration Table

What Do You Want To Do?

w

E = Tight Window Limits. Channel F = Standard Window Limits

x 8

Token material outside

acceptable limits

x 7

Token diameter outside

acceptable limits

x 6

Check that there are no mixed

sample tokens 

Token thickness outside

acceptable limits

x 5

Ensure that the rotary switch is

set to “F”

Incorrectly set rotary

switch position

x 4

Ensure at least 10 tokens have

been inserted

Not enough sample tokens

inserted

x 3

No activity was registered

within 30 seconds

Validator timed out

x 2

Reason/Action

Description

for Code

LED

Flashes

Teaching Token (

LED

 Assistance Codes)

Normal Operation Settings

2

3

4

ON

1

2

3

4

ON

1

Set switches 2, 3 & 4

to ON or OFF

No power to validator

OFF

Validator is set in teach mode

Flashing

Coin inhibited by validator or machine

4 x Flash

Coin inhibited by validator 

3 x Flash

Coin rejected as unrecognised

2 x Flash

Reject lever pressed or coin accepted

1 x Flash

Power is 

ON

 validator is O.K.

ON

MEANING

STATE

What Is The Green 

LED

 Doing?

Using 4 Way DIL & Rotary Data Switches

To achieve a successful change to the configuration of the

validator the following procedure must be followed.

1.

Switch 

OFF

 the power to the validator.

2.

Set the 4 way 

DIL

 switches to the configuration

settings required. (See Product Configuration

Table)

3.

Select the required data / channel position using

the rotary data switch. (see product configuration
table)

4.

Switch the  validator power 

ON

. (The 

LED

 will

start flashing).

5.

Return the 4 way 

DIL

 teach switches back to

Normal Operation Settings. (Switches 2,3 & 4 set

to all 

ON

 or all 

OFF

).

6.

The 

LED

 will stop flashing and will stay 

ON

. This

will indicate a successful change and that the

validator is ready for normal operation.

NOTE:- If teach is entered by mistake, switch 

OFF

 the

power to the  validator before moving the 4 way 

DIL

switch positions else the mech. may learn

 

something

unintentionally.