Teaching a New Token
The following procedure must be followed in order to teach
a new token into channel 1.
NOTE:- Rotary data switch position “E” is used to
program tight window token limits and ‘F’ standard
window token limits.
1.
Switch
OFF
the power to the validator.
2.
Set the 4 way
DIL
teach switches 2, 3 & 4 to
ON,
ON
&
OFF
(channel 1) or OFF, ON & ON for
(channel 0)
3.
Set rotary data switch to position “F” standard
window limit.
4.
Switch
ON
the power to the product.
(The
LED
will start flashing).
5.
Insert 10 to 20 (minimum 10) of the desired
tokens through the validator.
6.
Return the 4 way
DIL
switches 2, 3 & 4 to
Normal Operation settings.
(
LED
will stop flashing and stay
ON
to indicate
success).
If the
LED
continues to flash
OFF
a number of
times this indicates a failure to teach the new
token. See
LED
Assistance Codes table for help
and then restart procedure again.
7.
Token is now programmed and ready to use.
(New token information has been stored in coin
channel “1” which is rotary switch position “1”).
Any previous taught token information in this
channel will be overwritten).
NOTE:- If token self teach is successful but token
taught is rejected i.e. gives 3 flashes of the
LED,
check
that channel “1” is enabled.
To enable the new token set the rotary data switch to
position “1” then refer to enabling coin or tokens
configuration procedure).
Product Configuration
-
F
Auto configuration
-
D
Parallel output
ON
OFF
OFF
-
C
Binary coded output
Selecting Machine Interface Types
-
-
-
OFF
-
Set the alarm
OFF
-
-
-
ON
-
Set the alarm
ON
ON
OFF
OFF
-
0 - 7
Change overflow default exit route
ON
OFF
ON
-
E
Fraud Defence teach channel 0
OFF
ON
ON
-
s
E or F
Self teach a token for channel 1
ON
ON
OFF
-
s
E or F
Self teach a token for channel 0
OFF
ON
ON
-
0 - D
Token group for channel 1
ON
ON
OFF
-
0 - D
Token group for channel 0
OFF
OFF
ON
-
0 - F
Enable a coin or token channel
OFF
ON
OFF
-
0 - F
Inhibit a coin or token channel
SW4
SW3
SW2
SW1
2
3
4
ON
1
2
3
4
ON
1
Channel
Position
Product Configuration Table
What Do You Want To Do?
w
E = Tight Window Limits. Channel F = Standard Window Limits
x 8
Token material outside
acceptable limits
x 7
Token diameter outside
acceptable limits
x 6
Check that there are no mixed
sample tokens
Token thickness outside
acceptable limits
x 5
Ensure that the rotary switch is
set to “F”
Incorrectly set rotary
switch position
x 4
Ensure at least 10 tokens have
been inserted
Not enough sample tokens
inserted
x 3
No activity was registered
within 30 seconds
Validator timed out
x 2
Reason/Action
Description
for Code
LED
Flashes
Teaching Token (
LED
Assistance Codes)
Normal Operation Settings
2
3
4
ON
1
2
3
4
ON
1
Set switches 2, 3 & 4
to ON or OFF
No power to validator
OFF
Validator is set in teach mode
Flashing
Coin inhibited by validator or machine
4 x Flash
Coin inhibited by validator
3 x Flash
Coin rejected as unrecognised
2 x Flash
Reject lever pressed or coin accepted
1 x Flash
Power is
ON
validator is O.K.
ON
MEANING
STATE
What Is The Green
LED
Doing?
Using 4 Way DIL & Rotary Data Switches
To achieve a successful change to the configuration of the
validator the following procedure must be followed.
1.
Switch
OFF
the power to the validator.
2.
Set the 4 way
DIL
switches to the configuration
settings required. (See Product Configuration
Table)
3.
Select the required data / channel position using
the rotary data switch. (see product configuration
table)
4.
Switch the validator power
ON
. (The
LED
will
start flashing).
5.
Return the 4 way
DIL
teach switches back to
Normal Operation Settings. (Switches 2,3 & 4 set
to all
ON
or all
OFF
).
6.
The
LED
will stop flashing and will stay
ON
. This
will indicate a successful change and that the
validator is ready for normal operation.
NOTE:- If teach is entered by mistake, switch
OFF
the
power to the validator before moving the 4 way
DIL
switch positions else the mech. may learn
something
unintentionally.