background image

13

SHORTCUT function

Press SHORTCUT button(some units)

Push this button when remote controller is on, the system will automatically

revert back to the previous settings including operating mode, setting 

temperature, fan speed level and sleep feature (if activated).    
If pushing more than 2 seconds, the system will automatically restore the

current operation settings including operating mode, setting temperature,

fan speed level and sleep feature (if activated ).

Clean Function

Press CLEAN button

Airborne bacteria can grow in the moisture that condenses around heat exchanger 

in the unit. With regular use, most of this moisture is evaporated from the unit. 

By pressing the CLEAN button, your unit will clean itself automatically. After cleaning, 

the unit will turn off automatically. Pressing the CLEAN button mid-cycle will cancel

the operation and turn off the unit.  You can use CLEAN as often as you like. 

Note

: You can only activate this function  in COOL or DRY mode.

Clean

TURBO Function

Press TURBO button

Turbo

When you select Turbo feature in COOL mode, the unit will blow cool air

with strongest wind setting to jump-start the cooling process.

When you select Turbo feature in HEAT mode, for units with Electric heat

elements, the Electric HEATER will activate and  jump-start the heating

process.

Summary of Contents for Comfort-Aire Century DVH 09 Series

Page 1: ...Remote Controller Manual DVH 09 12 18 24 Series Inverter Single Zone Ductless Mini Split www marsdelivers com ...

Page 2: ...ble of Contents Remote Controller Specifications 02 Handling the Remote Controller 03 Buttons and Functions 04 Remote Screen Indicators 07 How to Use Basic Functions 08 How to Use Advanced Functions 11 01 ...

Page 3: ...d USER S MANUAL on function description the description of USER S MANUAL shall prevail 02 Remote Controller Specifications Quick Start Guide RG10B D BGEF RG10B D1 BGEFU1 RG10B1 D BGEF RG10B2 D BGCEF RG10B10 D BGEF RG10A4 D BGEF RG10A4 D1 BGEFU1 RG10A5 D BGEF RG10A5 D1 BGEFU1 RG10A5 D1 BGCEFU1 RG10A5 D BGCEF RG10A11 D BGEF 8m 3 0V Dry batteries R03 LR03 2 5 C 60 C 23 F 140 F FIT BATTERIES POINT REM...

Page 4: ... the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide...

Page 5: ...K button to confirm Used to start stop the Self Clean function Turns indoor unit s LED display and air conditioner buzzer on and off model dependent which create a comfortable and quiet environment FAN SPEED TEMP Enables unit to reach preset temperature in shortest possible time Selects fan speeds in the following order AUTO LOW MED HIGH NOTE Holding this button down for 2 seconds will activate Si...

Page 6: ...unction Turns indoor unit s LED display and air conditioner buzzer on and off model dependent which create a comfortable and quiet environment FAN SPEED TEMP Enables unit to reach preset temperature in shortest possible time Selects fan speeds in the following order AUTO LOW MED HIGH NOTE Holding this button down for 2 seconds will activate Silence feature Decreases temperature in 1 C increments M...

Page 7: ...h create a comfortable and quiet environment FAN SPEED TEMP Enables unit to reach preset temperature in shortest possible time Selects fan speeds in the following order AUTO LOW MED HIGH NOTE Holding this button down for 2 seconds will activate Silence feature SHORTCUT Used to restore the current settings or resume previous settings Model NOTE For models of RG10A4 D1 BGEFU1 RG10A5 D1 BGEFU1 and RG...

Page 8: ... me feature display Wireless control feature display Low battery detection display If flashes Displays when LOCK feature is activated Lights up when remote sends signal to indoor unit Displays the current including mode Displays when ECO feature is activated LOW MED HIGH AUTO Displays selected fan speed This fan speed can not be adjusted in AUTO or DRY mode Fresh feature display some units No disp...

Page 9: ...TEMP or TEMP button Set your desired temperature using the TEMP or TEMP button 3 Press the ON OFF button to start the unit Press the ON OFF button to start the unit NOTE FAN SPEED can t be set in AUTO mode COOL Mode Basic operation 1 Press the MODE button to select COOL mode 2 3 Press FAN button to select the fan speed AUTO LOW MED or HIGH 4 1 3 2 1 3 2 4 SETTING TEMPERATURE The operating temperat...

Page 10: ... ON OFF button to start the unit 1 Press the MODE button to select HEAT mode 2 3 Press FAN button to select the fan speed AUTO LOW MED or HIGH 4 4 1 3 2 1 3 2 DRY Mode dehumidifying NOTE FAN SPEED cannot be changed in DRY mode HEAT Mode NOTE As outdoor temperature drops the performance of your unit s HEAT function may be affected In such instances we recommend using this air conditioner in conjunc...

Page 11: ...ter 24 2 Cancel either function by setting its timer to 0 0h Point remote to unit and wait 1sec the TIMER ON will be activated Press TIMER button to initiate the OFF time sequence Point remote to unit and wait 1sec the TIMER OFF will be activated Current time 1PM 2 00PM 3 00PM 4PM 5PM 6PM Timer starts Unit turns ON Unit turns OFF 2 5 hours later 5 hours later 3 30PM Example If current timer is 1 0...

Page 12: ...he actual room temperature Press more than 5 seconds again will revert back to display the setting temperature Press this button to turn on and turn off the display on the indoor unit 5s Press LED button Press this button more than 5 seconds some units Keep pressing Fan button for more than 2 seconds to activate disable Silence function some units Due to low frequency operation of compressor it ma...

Page 13: ... the ECO button again to stop it O O O O O O O O O O Clean Press ECO button to enter the energy efficient mode Note This function is only available under COOL mode ECO operation 5s 5s Turbo The unit will operate at high fan speed while compressor on with temperature automatically set to 8 C 46 F Note This function is for heat pump air conditioner only 2 Press together Clean button and Turbo button...

Page 14: ...ses around heat exchanger in the unit With regular use most of this moisture is evaporated from the unit By pressing the CLEAN button your unit will clean itself automatically After cleaning the unit will turn off automatically Pressing the CLEAN button mid cycle will cancel the operation and turn off the unit You can use CLEAN as often as you like Note You can only activate this function in COOL ...

Page 15: ...signal to the air conditioner every 3 minutes interval When using AUTO COOL or HEAT modes measuring ambient temperature from the remote control instead of from the indoor unit itself will enable the air conditioner to optimize the temperature around you and ensure maximum comfort If the memory feature is stopped OF displays for 3 seconds on the screen While the memory feature is activated press th...

Page 16: ...FWXDO SURGXFW SULRU WR EHJLQQLQJ DQ LQVWDOODWLRQ SUHSDUDWLRQV QFHQWLYH DQG UHEDWH SURJUDPV KDYH SUHFLVH UHTXLUHPHQWV DV WR SURGXFW SHUIRUPDQFH DQG FHUWLILFDWLRQ OO SURGXFWV PHHW DSSOLFDEOH UHJXODWLRQV LQ HIIHFW RQ GDWH RI PDQXIDFWXUH KRZHYHU FHUWLILFDWLRQV DUH QRW QHFHVVDULO JUDQWHG IRU WKH OLIH RI D SURGXFW 7KHUHIRUH LW LV WKH UHVSRQVLELOLW RI WKH DSSOLFDQW WR GHWHUPLQH ZKHWKHU D VSHFLILF PRGHO T...