background image

ITEMS INCLUDED IN THE PACKAGE

●   Base part with platform and adjusting feet & 2m cord with indicator

●   5 pcs plastic wall plugs (2 pcs as spare part)  

●   5 pcs M3x25 screws (2 pcs as spare part)  

●   1 pc 5x75 crosshead screwdriver  

●   Instruction Manual

●   Assembly Manual

PROCEDURES & INSTRUCTIONS FOR ASSEMBLING REMOTE INDICATOR 

ON THE WALL

The indicator has a 2m cable to allow it to be placed at a convenient position away from the 

scale. A multi-function bracket allows the indicator to be wall mounted or sat upon a desk.

7

6

      

IMPORTANT NOTICE TO USERS!

1. Choose the location to mount the indicator on the wall. The location should be free  

of temperature extremes and water. It should be where it is within easy reach of the 
operator.

2. Make sure the structure and mounting hardware are of sufficient strength to support  

the indicator. The multi-function bracket should be securely fastened to the wall so 

that it cannot loose from the mounting surface.

1.  Use the multi-function bracket as a template and mark the 3 holes on the wall. Remove  

the bracket and then drill the holes.

Holes

2. Insert three wall plugs into the holes until the wall plugs are flush with the wall. Place the  

indicator against the wall and insert 3pcs M3x25 screws through the bracket into the 

wall plugs. Then use neck lock to adjust the angle of the indicator.

Neck lock

Wall plugs

M3x25 Screws

-  ▼  : Toggle between “on” or “off” in setting mode; Move cursor to right;  

decrease value of age; toggle between male and female; toggle between 

normal and athlete mode; select memory location

-        : Store settings into memory; replay the last measurement result 

-        : Confirm button for selection

-   

      

: Tare function in weighing mode

-             : Enter into height measuring mode

 PREPARATION BEFORE USE

1.  Connect the Power or Insert the Batteries

Insert 6pcs x 1.5V AA alkaline batteries (included) into the battery compartment located 

at the back of the indicator, or power up the scale through connecting the AC/DC adaptor 

(included) with the power socket.

        

SAFETY

To avoid injury, do not step 
on the edge of the platform.

Do not stop on scale unerenly

2.  Correct Positionig 

Use the scale on a flat and hard floor surface.   

3.  Setting the level

Before you use the scale for the first time or when 

the scale has been moved to another place, the level 

of the scale must be set.

A.  Don’t step on the scale and remove all weight   

from the platform.

B.  Place the scale on hard and flat surface, use the   

adjustable feet to adjust the spirit level until the 

bubble inside the level indicator is located in the 

centre of the circle.

Level indicator

Bubble

Circle

Summary of Contents for BFA-220R

Page 1: ...00 169 2775 SALES HEAD OFFICE Anvil House Tuns Lane Henley on Thames Oxfordshire RG9 1SA Tel 0845 130 7330 Fax 0845 130 7440 MANUFACTURING Unit 7 Centurion Business Park Coggin Mill Way Rotherham S60 1FB Tel 01709 364296 Fax 01709 364293 www marsden weighing co uk email sales marsdengroup co uk ...

Page 2: ...mplants such as pacemaker artificial limbs contraceptive devices metal plates or screws It may cause the devices to malfunction or produce an inaccurate result When in doubt please consult your physician Do not disassemble the scale as incorrect handling may cause injury TYPE FM 622 220X INTRODUCTION NOTES ON SAFETY INTENDED USED SAFETY NOTICE IMPORTANT NOTICE TO USERS PRODUCT DESCRIPTION FRONT VI...

Page 3: ... in bare feet Keyboard Remote indicator Height rod LCD display Spirit level Mounting bracket Adjustable feet DC jack Platform with electrodes KEY DESCRIPTION RJ11 port Neck lock Bracket 6 pcs AA battery compartment WEIGHT Weighing mode HEIGHT Height measuring mode BMI BMI mode 0 Indicates that the scale is set to zero NET Tare function in use STA Indicates a stable reading HOLD Indicates hold of w...

Page 4: ...gainst the wall and insert 3pcs M3x25 screws through the bracket into the wall plugs Then use neck lock to adjust the angle of the indicator Neck lock Wall plugs M3x25 Screws Toggle between on or off in setting mode Move cursor to right decrease value of age toggle between male and female toggle between normal and athlete mode select memory location Store settings into memory replay the last measu...

Page 5: ...measuring process memory mode Note I D No 0000 will be shown in memory recall mode once you return the I D setting from off to on Heels centered on electrodes Heels not touching the electrode X Fig 3 2 Estimation Mode Setting Users can select their desired estimation mode Body fat with fat mass and fat free mass estimation Fig 4a body water percentage Fig 4b muscle mass Fig 4c and or bone mass Fig...

Page 6: ...ing into BMI mode 2 o will cycle along the LCD Fig 5 Step on the scale when the screen showing stEP Fig 14 3 Set ID No Available when I D No set on will be shown on LCD Fig 15 Enter 4 digits by numeric keys and press to confirm Or press CE to input ID No again 4 Push down the rod completely It will switch off automatically once it remains idle for 20 seconds BMI MEASURING OPERATION Fig 16 4 Set BM...

Page 7: ... Body Fat Estimation Mode Press key all digits Fig 1 and software version Fig 2 will be shown on LCD successively then bMI will be displayed on LCD Fig 13 Press key again and bFA will be displayed on LCD Fig 18 Press to confirm then o will cycle along the LCD Fig 5 2 Step on the scale with bare feet when the screen showing stEP Fig 14 3 Set ID NO Available when I D No set on will be shown on LCD F...

Page 8: ...0 24 to select memory location Press to confirm the memory location 3 If the memory is empty will be displayed Fig 27 Press or or numeric keys 0 24 to select another memory location 4 If the memory is occupied memorised BMI parameters will be shown on screen ID No and height will be toggled on screen Press to confirm and o will cycle on screen 5 Follow steps 6 7 in the section of BMI MEASURING OPE...

Page 9: ...The message displays Err 2 when measuring Overload warning Remove the weight immediately otherwise permanent damage to the scale may occur 5 Unable to hold weight Check whether your weight is stable If not please wait until STA icon is shown on screen and then press again 6 The message displays Err 3 when estimating body fat and body water values Contact error Impedance cannot be measured Please m...

Page 10: ...put for height measuring rod Multi functional desk top and wall mount bracket With AC DC Jack input adaptor included Capacity 220 kg Graduation 0 1kg Body fat and body water graduation 0 1 Fat mass and fat free mass graduation 0 1kg Muscle mass and bone mass graduation 0 1kg Age range from 10 to 99 years Height range 110 to 200cm for height rod measurement 100 to 220cm for manual input Height grad...

Page 11: ...ydration level prior to the estimation The accuracy of the scale in estimating TBW will also decrease with individuals suffering from diseases that tend to accumulate water in the body BF Range Optimal TBW Range Men 4 to 14 70 to 63 15 to 21 63 to 57 22 to 24 57 to 55 25 and over 55 to 37 Women 4 to 20 70 to 58 21 to 29 58 to 52 30 to 32 52 to 49 33 and over 49 to 37 The optimal TBW of an individu...

Page 12: ...e is approximately between 2 7 and 3 5 kg Rico et al 1993 For Children The average bone mineral content of 8 16 year old child is approximately between 0 8 and 2 2 kg Faulkner et al 1993 9 What is Fat Mass Fat Mass is the total weight of fat mass in the body 10 What is Fat free Mass Our Body Fat Scale estimates the weight of fat free mass in your body Fat free mass is comprised of the nonfat compo...

Page 13: ... telephone product support For information on any of our scales phone Freefone 0800 169 2775 and ask for Product Support PRICE PRODUCT INFORMATION Prices are shown without VAT Stamping fees for approved models are included unless otherwise stated Specification may alter due to a policy of continued product development RETURNS POLICY Scales returned due to Marsden error no charge Order placed is in...