background image

10

11

HOLD FUNCTION

In weighing mode, the weight can be held to let user 

clearly read the information.

1.  Follow steps 1-3 in the section of 

WEIGHING ONLY  

OPERATION

.

2.  Press 

[         ]

 to hold the weight, the weight with hold  

icon will be shown on screen (Fig.8). If weight is unstable, "hold" iocn will blink. 

3.  Press 

[         ] 

again to release the weight, or it will switch 

     off automatically once it remains idle for 20 seconds.

Fig.8

Fig.9

Fig.10

1.  Press

 [HEIGHT]

 key to enter into height measuring mode, 

     all digits (Fig.1) and software version (Fig.2) will be shown  

     on LCD successively, then “-” will cycle along the LCD (Fig.9).

2.  The default height value (110.0cm) will be displayed with  

height indication (Fig.10).  

Note: 

If the screen displays “----” (Fig.11a), push down 

the height rod until the cursor meets the head of the outer 

column (Fig.11b).

HEIGHT MEASURING OPERATION (FUNCTION AVAILABLE WITH THE 

ELECTRONIC HEIGHT ROD ONLY)

Fig.11a

Fig.11b

Head of outer column

Cursor

3.  Stand straight towards the height rod. Lift the rod up till the cursor is lying horizontally on     

your head (Fig.12a), the height will display (Fig.12b). 

Fig.12a

Fig.12b

Fig.13

Fig.14

Fig.15

1.  

Enter Into BMI Mode

Press 

[              ]

 key, all digits (Fig.1) and software 

version (Fig.2) will be shown on LCD successively, then 

“bMI” will be displayed on LCD (Fig.13). Press [       ] to 

confirm entering into BMI mode.

2.  “o” will cycle along the LCD (Fig.5). Step on the scale    

when the screen showing “stEP” (Fig.14).

3.  

Set ID No. (Available when I.D. No. set “on”)

“----” will be shown on LCD (Fig.15). Enter 4 digits by 

numeric keys and press [       ] to confirm. Or press 

[CE]

 

to input ID No. again.

4.  Push down the rod completely. It will switch off automatically once it remains idle for 20 seconds.

BMI MEASURING OPERATION

Fig.16

4. 

 Set BMI Parameter

     4.1 Set Height 

A. When using the scale equipped with a height rod, the 

height value will be input from the electronic height rod. 

Stand on the floor with bare feet, then follow the steps 

of 

HEIGHT  MEASURING  OPERATION

  to  measure 

your height. However, you are still allowed to input your 

height value manually even when the scale is equipped 

with height measuring rod. Press

 [CE]

 and input height 

by numeric keys.

B. When using the scale without height rod, you can set 

the height value manually. Input your 4 digit height using 

the numeric keys.

5.  Press [       ] to confirm your height.

6.

  Measuring

Step  on  the  scale.  Stand  still  while  the  weight  is 

measured. “STA” will be shown if the weight is stable 

(Fig.16).

  

C

IMPORTANT NOTICE TO USERS

●   A few steps must be followed before measuring BMI.

     

PROGRAM PERSONAL PARAMETER

Input the user’s height before BMI measurement. Once the information is memorised,  

it will only need to be re-entered if there is a change to the data.

●  Ensure data input for each personal parameter is completed within 20 seconds 

     otherwise the scale will switch off automatically.

Summary of Contents for BFA-220R

Page 1: ...00 169 2775 SALES HEAD OFFICE Anvil House Tuns Lane Henley on Thames Oxfordshire RG9 1SA Tel 0845 130 7330 Fax 0845 130 7440 MANUFACTURING Unit 7 Centurion Business Park Coggin Mill Way Rotherham S60 1FB Tel 01709 364296 Fax 01709 364293 www marsden weighing co uk email sales marsdengroup co uk ...

Page 2: ...mplants such as pacemaker artificial limbs contraceptive devices metal plates or screws It may cause the devices to malfunction or produce an inaccurate result When in doubt please consult your physician Do not disassemble the scale as incorrect handling may cause injury TYPE FM 622 220X INTRODUCTION NOTES ON SAFETY INTENDED USED SAFETY NOTICE IMPORTANT NOTICE TO USERS PRODUCT DESCRIPTION FRONT VI...

Page 3: ... in bare feet Keyboard Remote indicator Height rod LCD display Spirit level Mounting bracket Adjustable feet DC jack Platform with electrodes KEY DESCRIPTION RJ11 port Neck lock Bracket 6 pcs AA battery compartment WEIGHT Weighing mode HEIGHT Height measuring mode BMI BMI mode 0 Indicates that the scale is set to zero NET Tare function in use STA Indicates a stable reading HOLD Indicates hold of w...

Page 4: ...gainst the wall and insert 3pcs M3x25 screws through the bracket into the wall plugs Then use neck lock to adjust the angle of the indicator Neck lock Wall plugs M3x25 Screws Toggle between on or off in setting mode Move cursor to right decrease value of age toggle between male and female toggle between normal and athlete mode select memory location Store settings into memory replay the last measu...

Page 5: ...measuring process memory mode Note I D No 0000 will be shown in memory recall mode once you return the I D setting from off to on Heels centered on electrodes Heels not touching the electrode X Fig 3 2 Estimation Mode Setting Users can select their desired estimation mode Body fat with fat mass and fat free mass estimation Fig 4a body water percentage Fig 4b muscle mass Fig 4c and or bone mass Fig...

Page 6: ...ing into BMI mode 2 o will cycle along the LCD Fig 5 Step on the scale when the screen showing stEP Fig 14 3 Set ID No Available when I D No set on will be shown on LCD Fig 15 Enter 4 digits by numeric keys and press to confirm Or press CE to input ID No again 4 Push down the rod completely It will switch off automatically once it remains idle for 20 seconds BMI MEASURING OPERATION Fig 16 4 Set BM...

Page 7: ... Body Fat Estimation Mode Press key all digits Fig 1 and software version Fig 2 will be shown on LCD successively then bMI will be displayed on LCD Fig 13 Press key again and bFA will be displayed on LCD Fig 18 Press to confirm then o will cycle along the LCD Fig 5 2 Step on the scale with bare feet when the screen showing stEP Fig 14 3 Set ID NO Available when I D No set on will be shown on LCD F...

Page 8: ...0 24 to select memory location Press to confirm the memory location 3 If the memory is empty will be displayed Fig 27 Press or or numeric keys 0 24 to select another memory location 4 If the memory is occupied memorised BMI parameters will be shown on screen ID No and height will be toggled on screen Press to confirm and o will cycle on screen 5 Follow steps 6 7 in the section of BMI MEASURING OPE...

Page 9: ...The message displays Err 2 when measuring Overload warning Remove the weight immediately otherwise permanent damage to the scale may occur 5 Unable to hold weight Check whether your weight is stable If not please wait until STA icon is shown on screen and then press again 6 The message displays Err 3 when estimating body fat and body water values Contact error Impedance cannot be measured Please m...

Page 10: ...put for height measuring rod Multi functional desk top and wall mount bracket With AC DC Jack input adaptor included Capacity 220 kg Graduation 0 1kg Body fat and body water graduation 0 1 Fat mass and fat free mass graduation 0 1kg Muscle mass and bone mass graduation 0 1kg Age range from 10 to 99 years Height range 110 to 200cm for height rod measurement 100 to 220cm for manual input Height grad...

Page 11: ...ydration level prior to the estimation The accuracy of the scale in estimating TBW will also decrease with individuals suffering from diseases that tend to accumulate water in the body BF Range Optimal TBW Range Men 4 to 14 70 to 63 15 to 21 63 to 57 22 to 24 57 to 55 25 and over 55 to 37 Women 4 to 20 70 to 58 21 to 29 58 to 52 30 to 32 52 to 49 33 and over 49 to 37 The optimal TBW of an individu...

Page 12: ...e is approximately between 2 7 and 3 5 kg Rico et al 1993 For Children The average bone mineral content of 8 16 year old child is approximately between 0 8 and 2 2 kg Faulkner et al 1993 9 What is Fat Mass Fat Mass is the total weight of fat mass in the body 10 What is Fat free Mass Our Body Fat Scale estimates the weight of fat free mass in your body Fat free mass is comprised of the nonfat compo...

Page 13: ... telephone product support For information on any of our scales phone Freefone 0800 169 2775 and ask for Product Support PRICE PRODUCT INFORMATION Prices are shown without VAT Stamping fees for approved models are included unless otherwise stated Specification may alter due to a policy of continued product development RETURNS POLICY Scales returned due to Marsden error no charge Order placed is in...

Reviews: