background image

14

15

Fig.25

The scale features 25 personal memory settings. This allows 

users to store and recall their own settings.

A. To Store Settings into Memory

1.  Follow steps 1-4 in the section of 

BMI MEASURING  

OPERATION.

2.  Press and hold [       ] key for 2 seconds to store up all  

settings,  “M”  with  last  memorised  location  will  blink 

(Fig.26). Press [▲] / [▼] or numeric keys 0-24 to select 

the memory location. Press [     ] to confirm memory 

locations. Or press [

CE

] to cancel and select another 

memory location again.

3.  If the memory is empty, “----” will be displayed (Fig.27).  

Press [       ] to confirm.

Fig.26

Fig.27

MEASURING BMI WITH USER MEMORY

4.  If the memory is occupied, “uSEd” will be displayed  

(Fig.28). Press [       ] to confirm. “CLEAr” will be displayed (Fig.29). Press [      ], the new 

settings will be memorised and replaced the previous setting.

5.  Follow steps 6-7 in the section of 

BMI MEASURING OPERATION.

Fig.28

Fig.29

Fig.30

B. To Recall Setting from Memory

1.  Press

 [                 ]

 key, all digits (Fig.1) and software 

     version (Fig.2) will be shown on LCD successively, then 

 

     “bMI” will be displayed on LCD (Fig.13). Press 

[                    ]

 

     key twice and “mem” will be displayed on LCD (Fig.30). 

2.  Press [     ] to confirm and it will enter into memory recall mode. “M” with last 

 

    memorised location will blink (Fig.26). Press [▲] or [▼] or numeric keys 0-24 to select 

 

     memory location. Press [       ] to confirm the memory location. 

3.  If the memory is empty, “----” will be displayed (Fig.27). Press [▲] or [▼] or numeric 

 

     keys 0-24 to select another memory location.

4.  If the memory is occupied, memorised BMI parameters will be shown on screen (ID   

 

    No, and height will be toggled on screen). Press [       ] to confirm and “o” will cycle     

 

     on screen.

5.  Follow steps 6-7 in the section of 

BMI MEASURING OPERATION.

ESTIMATING BODY FAT AND TOTAL BODY WATER WITH USER MEMORY

Fig.31

Fig.32

A.  

To Store Settings into Memory

1.  Follow steps 1-4 in the section of 

BODY FAT AND  

     TOTAL BODY WATER ESTIMATING OPERATION.

2.  Press and hold [       ] key for 2 seconds to store up all  

settings, last memorised location will blink with current 
setting on screen (Fig.31). Press [▲] / [▼] or numeric 
keys 0-24 to select the memory location. Press [      ] to 
confirm memory locations. Or press 

[CE] 

to cancel and 

select another memory location again.

3.  If the memory is empty, “----” with current setting will be    

shown on screen (Fig.32). Press [       ] to confirm.

4.  If the memory is occupied, “uSEd” with current setting 

will  be  displayed  (Fig.33).  Press  [          ]  to  confirm. 
“CLEAr” with current setting will be displayed (Fig.34). 
Press [      ], the new settings will be memorised and 
replace the previous setting.

5. Follow steps 6-8 in the section of 

BODY FAT AND 

     TOTAL BODY WATER ESTIMATING OPERATION.

Fig.33

Fig.34

  

C

IMPORTANT NOTICE TO USERS

● Do not step on the scale until "0.0kg" with "STA" indication shows on screen.

Summary of Contents for BFA-220R

Page 1: ...00 169 2775 SALES HEAD OFFICE Anvil House Tuns Lane Henley on Thames Oxfordshire RG9 1SA Tel 0845 130 7330 Fax 0845 130 7440 MANUFACTURING Unit 7 Centurion Business Park Coggin Mill Way Rotherham S60 1FB Tel 01709 364296 Fax 01709 364293 www marsden weighing co uk email sales marsdengroup co uk ...

Page 2: ...mplants such as pacemaker artificial limbs contraceptive devices metal plates or screws It may cause the devices to malfunction or produce an inaccurate result When in doubt please consult your physician Do not disassemble the scale as incorrect handling may cause injury TYPE FM 622 220X INTRODUCTION NOTES ON SAFETY INTENDED USED SAFETY NOTICE IMPORTANT NOTICE TO USERS PRODUCT DESCRIPTION FRONT VI...

Page 3: ... in bare feet Keyboard Remote indicator Height rod LCD display Spirit level Mounting bracket Adjustable feet DC jack Platform with electrodes KEY DESCRIPTION RJ11 port Neck lock Bracket 6 pcs AA battery compartment WEIGHT Weighing mode HEIGHT Height measuring mode BMI BMI mode 0 Indicates that the scale is set to zero NET Tare function in use STA Indicates a stable reading HOLD Indicates hold of w...

Page 4: ...gainst the wall and insert 3pcs M3x25 screws through the bracket into the wall plugs Then use neck lock to adjust the angle of the indicator Neck lock Wall plugs M3x25 Screws Toggle between on or off in setting mode Move cursor to right decrease value of age toggle between male and female toggle between normal and athlete mode select memory location Store settings into memory replay the last measu...

Page 5: ...measuring process memory mode Note I D No 0000 will be shown in memory recall mode once you return the I D setting from off to on Heels centered on electrodes Heels not touching the electrode X Fig 3 2 Estimation Mode Setting Users can select their desired estimation mode Body fat with fat mass and fat free mass estimation Fig 4a body water percentage Fig 4b muscle mass Fig 4c and or bone mass Fig...

Page 6: ...ing into BMI mode 2 o will cycle along the LCD Fig 5 Step on the scale when the screen showing stEP Fig 14 3 Set ID No Available when I D No set on will be shown on LCD Fig 15 Enter 4 digits by numeric keys and press to confirm Or press CE to input ID No again 4 Push down the rod completely It will switch off automatically once it remains idle for 20 seconds BMI MEASURING OPERATION Fig 16 4 Set BM...

Page 7: ... Body Fat Estimation Mode Press key all digits Fig 1 and software version Fig 2 will be shown on LCD successively then bMI will be displayed on LCD Fig 13 Press key again and bFA will be displayed on LCD Fig 18 Press to confirm then o will cycle along the LCD Fig 5 2 Step on the scale with bare feet when the screen showing stEP Fig 14 3 Set ID NO Available when I D No set on will be shown on LCD F...

Page 8: ...0 24 to select memory location Press to confirm the memory location 3 If the memory is empty will be displayed Fig 27 Press or or numeric keys 0 24 to select another memory location 4 If the memory is occupied memorised BMI parameters will be shown on screen ID No and height will be toggled on screen Press to confirm and o will cycle on screen 5 Follow steps 6 7 in the section of BMI MEASURING OPE...

Page 9: ...The message displays Err 2 when measuring Overload warning Remove the weight immediately otherwise permanent damage to the scale may occur 5 Unable to hold weight Check whether your weight is stable If not please wait until STA icon is shown on screen and then press again 6 The message displays Err 3 when estimating body fat and body water values Contact error Impedance cannot be measured Please m...

Page 10: ...put for height measuring rod Multi functional desk top and wall mount bracket With AC DC Jack input adaptor included Capacity 220 kg Graduation 0 1kg Body fat and body water graduation 0 1 Fat mass and fat free mass graduation 0 1kg Muscle mass and bone mass graduation 0 1kg Age range from 10 to 99 years Height range 110 to 200cm for height rod measurement 100 to 220cm for manual input Height grad...

Page 11: ...ydration level prior to the estimation The accuracy of the scale in estimating TBW will also decrease with individuals suffering from diseases that tend to accumulate water in the body BF Range Optimal TBW Range Men 4 to 14 70 to 63 15 to 21 63 to 57 22 to 24 57 to 55 25 and over 55 to 37 Women 4 to 20 70 to 58 21 to 29 58 to 52 30 to 32 52 to 49 33 and over 49 to 37 The optimal TBW of an individu...

Page 12: ...e is approximately between 2 7 and 3 5 kg Rico et al 1993 For Children The average bone mineral content of 8 16 year old child is approximately between 0 8 and 2 2 kg Faulkner et al 1993 9 What is Fat Mass Fat Mass is the total weight of fat mass in the body 10 What is Fat free Mass Our Body Fat Scale estimates the weight of fat free mass in your body Fat free mass is comprised of the nonfat compo...

Page 13: ... telephone product support For information on any of our scales phone Freefone 0800 169 2775 and ask for Product Support PRICE PRODUCT INFORMATION Prices are shown without VAT Stamping fees for approved models are included unless otherwise stated Specification may alter due to a policy of continued product development RETURNS POLICY Scales returned due to Marsden error no charge Order placed is in...

Reviews: