background image

16

17

B.  To Recall Setting from Memory

1.  Press 

[                   ]

 key, all digits (Fig.1) and software version (Fig.2) will be shown on 

     LCD successively, then “bMI” will be displayed on LCD (Fig.13). Press 

[                  ]

 

      key twice and “mem” will be displayed on LCD (Fig.30).

1.  Press [       ] key, all digits (Fig.1) and software version (Fig.2) will be shown on LCD  

successively, then “M” with last memorised location will be blinking (Fig.26).

2.  Press [▲] or [▼] or numeric key 0-24 to select memory location. Press [       ] to confirm.

3.  If the memory location is empty, “----” will display (Fig.27). Press [▲] / [▼] or input    

numeric key 0-24 to select another memory location.

4.  If the memory location is occupied, the ID No. and memorised personal data of BMI  

parameters (height) or BFA parameters (age, gender, normal/athlete, height) and the 

last BMI or BFA results will be shown on LCD, sequentially three times. Then it will 

turn off automatically.

REPLAY MEASURED DATA FROM MEMORY

  

C

IMPORTANT NOTICE TO USERS

● The screen will show "---.-" if no results or unsuccessful estimation is recorded in the  

    memory.

2.  Press [      ] to confirm and it will enter into memory recall mode. “M” with last memorised 

location will blink (Fig.31). Press [▲] or [▼] or numeric keys 0-24 to select memory 

location. Press [      ] to confirm the memory location.

3.  If the memory is empty, “----” will be displayed (Fig.32). Press [▲] or [▼] or numeric  

keys 0-24 to select another memory location.

4.  If the memory is occupied, memorised ID No. and BFA parameters (height, age, gender,  

normal or athlete selection) will be toggled on screen. Press [       ] to confirm and “o” will 

cycle on screen.

5.  Follow steps 6-8 in the section of 

BODY FAT AND TOTAL BODY WATER ESTIMATING  

OPERATION.

PROBLEM-SOLVING

1.  No weight display?

Check if the scale is powered up and started up. If not, please refer to the Section 

PREPARATION BEFORE USE

”.

2.  "bAtt" is displayed on screen.

     Battery is running low. Replace the battery.

3. The message displays “Err 0”….

The zero range is too great. Check if the platform is empty. If not, please remove 

the weight off the platform.

4. The message displays “Err 2” when measuring?

Overload warning. Remove the weight immediately; otherwise, permanent damage 

to the scale may occur.

5.  Unable to hold weight.

Check whether your weight is stable. If not, please wait until “STA” icon is shown 

on screen, and then press [

        

] again.

6.  The message displays “Err 3” when estimating body fat and body water   

values?

Contact error. Impedance cannot be measured. Please make sure that you are 

standing still on the scale and maintain maximum contact between your feet and 

the metal contacts. Please refer to Section “

Operation

”. You may need to moisten 

your feet to improve the electrical contact.

7. The message displays “Err 4” when estimating body fat and body water  

values?

Estimated body fat percentage is beyond the technical limit. Moistening of the feet 

may help to improve the electrical contact.

8.  The message displays “Err 5” when estimating body fat and body water  

values?

Percentage total body water is out of range. Moistening of the feet may help to 

improve the electrical contact.

9.  The message displays “Err6”…

Machine error. Please contact your supplier.

10.The message displays “---.-” when replay...

Unsuccessful  BMI  or  BFA  operation.  Follow  related  BMI  measuring  or  BFA 

estimating operation to complete your measurement.

11.The message displays “uStb” when measuring?

Unstable zero. Step off the scale, then step on the scale again.

12. After following corrective actions the problem still occurs.

If problem persists after following the corrective actions, disconnect the power 

supply and reconnect after 1 minute.

13.The message displays “Adc”?

 Machine error. Please contact your supplier.

14.The message displays “EEP”?

Machine error. Please contact your supplier.

15.The message displays “N.A”?

Without height rod. Check whether you have installed the height rod or the rod 

signal cable has connected with RJ11 port. If not, Install height rod according to 

related session in 

Electronic Height Measuring Rod Instruction Manual

.

16.I have tried all corrective actions, but still can’t solve the problem …

Please contact your supplier.

  

C

IMPORTANT NOTICE TO USERS

● Do not step on the scale until "0.0kg" with "STA" indication shows on screen.

Summary of Contents for BFA-220R

Page 1: ...00 169 2775 SALES HEAD OFFICE Anvil House Tuns Lane Henley on Thames Oxfordshire RG9 1SA Tel 0845 130 7330 Fax 0845 130 7440 MANUFACTURING Unit 7 Centurion Business Park Coggin Mill Way Rotherham S60 1FB Tel 01709 364296 Fax 01709 364293 www marsden weighing co uk email sales marsdengroup co uk ...

Page 2: ...mplants such as pacemaker artificial limbs contraceptive devices metal plates or screws It may cause the devices to malfunction or produce an inaccurate result When in doubt please consult your physician Do not disassemble the scale as incorrect handling may cause injury TYPE FM 622 220X INTRODUCTION NOTES ON SAFETY INTENDED USED SAFETY NOTICE IMPORTANT NOTICE TO USERS PRODUCT DESCRIPTION FRONT VI...

Page 3: ... in bare feet Keyboard Remote indicator Height rod LCD display Spirit level Mounting bracket Adjustable feet DC jack Platform with electrodes KEY DESCRIPTION RJ11 port Neck lock Bracket 6 pcs AA battery compartment WEIGHT Weighing mode HEIGHT Height measuring mode BMI BMI mode 0 Indicates that the scale is set to zero NET Tare function in use STA Indicates a stable reading HOLD Indicates hold of w...

Page 4: ...gainst the wall and insert 3pcs M3x25 screws through the bracket into the wall plugs Then use neck lock to adjust the angle of the indicator Neck lock Wall plugs M3x25 Screws Toggle between on or off in setting mode Move cursor to right decrease value of age toggle between male and female toggle between normal and athlete mode select memory location Store settings into memory replay the last measu...

Page 5: ...measuring process memory mode Note I D No 0000 will be shown in memory recall mode once you return the I D setting from off to on Heels centered on electrodes Heels not touching the electrode X Fig 3 2 Estimation Mode Setting Users can select their desired estimation mode Body fat with fat mass and fat free mass estimation Fig 4a body water percentage Fig 4b muscle mass Fig 4c and or bone mass Fig...

Page 6: ...ing into BMI mode 2 o will cycle along the LCD Fig 5 Step on the scale when the screen showing stEP Fig 14 3 Set ID No Available when I D No set on will be shown on LCD Fig 15 Enter 4 digits by numeric keys and press to confirm Or press CE to input ID No again 4 Push down the rod completely It will switch off automatically once it remains idle for 20 seconds BMI MEASURING OPERATION Fig 16 4 Set BM...

Page 7: ... Body Fat Estimation Mode Press key all digits Fig 1 and software version Fig 2 will be shown on LCD successively then bMI will be displayed on LCD Fig 13 Press key again and bFA will be displayed on LCD Fig 18 Press to confirm then o will cycle along the LCD Fig 5 2 Step on the scale with bare feet when the screen showing stEP Fig 14 3 Set ID NO Available when I D No set on will be shown on LCD F...

Page 8: ...0 24 to select memory location Press to confirm the memory location 3 If the memory is empty will be displayed Fig 27 Press or or numeric keys 0 24 to select another memory location 4 If the memory is occupied memorised BMI parameters will be shown on screen ID No and height will be toggled on screen Press to confirm and o will cycle on screen 5 Follow steps 6 7 in the section of BMI MEASURING OPE...

Page 9: ...The message displays Err 2 when measuring Overload warning Remove the weight immediately otherwise permanent damage to the scale may occur 5 Unable to hold weight Check whether your weight is stable If not please wait until STA icon is shown on screen and then press again 6 The message displays Err 3 when estimating body fat and body water values Contact error Impedance cannot be measured Please m...

Page 10: ...put for height measuring rod Multi functional desk top and wall mount bracket With AC DC Jack input adaptor included Capacity 220 kg Graduation 0 1kg Body fat and body water graduation 0 1 Fat mass and fat free mass graduation 0 1kg Muscle mass and bone mass graduation 0 1kg Age range from 10 to 99 years Height range 110 to 200cm for height rod measurement 100 to 220cm for manual input Height grad...

Page 11: ...ydration level prior to the estimation The accuracy of the scale in estimating TBW will also decrease with individuals suffering from diseases that tend to accumulate water in the body BF Range Optimal TBW Range Men 4 to 14 70 to 63 15 to 21 63 to 57 22 to 24 57 to 55 25 and over 55 to 37 Women 4 to 20 70 to 58 21 to 29 58 to 52 30 to 32 52 to 49 33 and over 49 to 37 The optimal TBW of an individu...

Page 12: ...e is approximately between 2 7 and 3 5 kg Rico et al 1993 For Children The average bone mineral content of 8 16 year old child is approximately between 0 8 and 2 2 kg Faulkner et al 1993 9 What is Fat Mass Fat Mass is the total weight of fat mass in the body 10 What is Fat free Mass Our Body Fat Scale estimates the weight of fat free mass in your body Fat free mass is comprised of the nonfat compo...

Page 13: ... telephone product support For information on any of our scales phone Freefone 0800 169 2775 and ask for Product Support PRICE PRODUCT INFORMATION Prices are shown without VAT Stamping fees for approved models are included unless otherwise stated Specification may alter due to a policy of continued product development RETURNS POLICY Scales returned due to Marsden error no charge Order placed is in...

Reviews: