16
Pressing the M+ key will cause the scale to display
the contents of the accumulator (the number of
pieces accumulated since the last time the
accumulator was cleared).
The M+ key is also used to add the current piece
count value to the accumulator. The M+
annunciator will be selected to indicate the
accumulation has taken place.
The PGM key is used to add or edit product look up
(PLU) numbers. Up to 99 PLU numbers can be
programmed. Note that the first 9 PLU’s are
assigned to the P1-9 keys and that all PLU’s can
be selected using the numeric keys.
Pressing the P# key will cause the scale to recall
the average piece weight along with the saved tare
weight (if a tare weight was programmed)
associated with the product look up (PLU) number.
P1 ~ P9
Pressing these keys will cause the scale to recall
the average piece weight along with the saved tare
weight (if a tare weight was programmed)
associated with the product look up (PLU) number
assigned to the key.
These keys are used to enter numeric data during
normal operations as well as during calibration and