29
3.
– Backlight Mode
With
, btli displayed the current setting for the Backlight
Mode parameter will be shown. If the setting displayed is
acceptable, press the UNITS key to proceed to the next
parameter.
Otherwise, use the TARE key to toggle between the selections
and then press the UNITS key to save it and proceed to the next
parameter. The available settings are:
= Auto Backlight – While weighing, the backlight will be
turned ON automatically when the weight is over 10
divisions or any key is pressed. The backlight will turn
OFF automatically when the scale has not been used
for 10 minutes.
= The will be no backlight (always OFF).
= The backlight will always be ON.
4.
– Automatic Power-Off
With
,
displayed the current setting for the
Automatic Shut-Off function parameter will be shown. If the
setting displayed is acceptable, press the UNITS key to proceed
to the next parameter.
Otherwise, use the TARE key to toggle between the selections
and then press the UNITS key to save it and proceed to the next
parameter. The available settings are:
120s
= After 120 seconds (2 minutes) of no activity the scale will
shut off and must be turned on using the ON/OFF switch.