6. Firmware update

 

NB!  Before  updating  to  new  firmware  read  the  setup  from  your  device,  and 

make a backup. 

 

  Run 

GWS.exe

 and set up SSH connection with the device 

  Press  the 

Upd

  button  next  to 

R  W  C 

buttons 

  If you have compressed .7z firmware update 

file (provided by Martem AS) choose  

Update 

From File

 

  If  you  do  not  have  .7z  firmware  update  file  choose 

Check  martem.ee

  to 

refresh exsisting firmware versions list for this AGC-L device 

  Press 

Update  to  feature

  and  choose  needed firmware  version.  Download  is 

starting... 

  After firmware is downloaded 

Confirm

 window appears. Press 

Yes

 button, the 

update process starts 

  Wait until the device resumes to its normal operation state (

RUN

 LED will start 

slow blinking again) 

  Firmware update is complete. 

 

Checking results of the firmware update operation:

 

  Press 

R

  button to read back the device setup data 

  Check the 

Version

 from GWS 

Status

 tab

 

 

Summary of Contents for TELEM-AGC-L

Page 1: ...Street lighting controller TELEM AGC L User Manual Martem AS 2018...

Page 2: ...3 2 FEATURES 3 3 TECHNICAL DATA 4 4 TERMINAL CONNECTORS 7 5 COMMUNICATION CABLES 8 6 FIRMWARE UPDATE 9 7 DIP SWITCHES 10 8 INDICATION LED S 10 9 CONFIGURATION TOOL 10 10 ORDER CODE 11 11 OPEN SOURCE...

Page 3: ...d choice for solutions where older and newer individually controlled LED luminaries are in same control network 2 Features Autonomous control without need of permanent connection to control center bas...

Page 4: ...ge protocols via Ethernet and serial ports An user friendly free configuration tool Configurable remotely over communication line Configuration export import to from CSV format files Charger for exter...

Page 5: ...nnectors 8 optically isolated digital inputs wet contacts with internal supply 4 relay outputs max 0 5 A 250 VAC 0 25 A 220 VDC Expansion modules Module A 8 optically isolated digital inputs wet conta...

Page 6: ...61000 4 2 Withstand to bursts surges IEC 61000 4 4 61000 4 5 Power frequency magnetic field IEC 61000 4 8 Voltage dips variations IEC 61000 4 11 Mechanical parameters Degree of protection IP 31 Dimens...

Page 7: ...GC L MAIN BOARD FRONT PANEL DOWNSIDE 1 WIRE SENSORS SIM 1 Radio Modem Antenna GPRS Antenna 13 C 14 C 15 C 16 C COMMON DI 13 DI 14 DI 15 DI 16 DO 6 DO 7 DO 8 9 C 10 C 11 C 12 C DI 9 DI 10 DI 11 DI 12 D...

Page 8: ...AS Martem Street Lighting Controller TELEM AGC L User Manual Rev 1 2018 AS MARTEM Tel 372 639 7979 martem martem eu www martem eu 8 5 Communication cables...

Page 9: ...AS choose Update From File If you do not have 7z firmware update file choose Check martem ee to refresh exsisting firmware versions list for this AGC L device Press Update to feature and choose needed...

Page 10: ...DFT SET back to OFF state when the alert indication LED is blinking to apply default setup If DFT SET is switched back to OFF state when the alert indication LED is not blinking default setup will NOT...

Page 11: ...ion R Radio N No GPRS modem 3 3G 4 4G N No Expansion module A 8 DI 4 DO B 8 DI 3 DO DALI F 16 DI 8 DO G 16 DI 7 DO DALI N No 11 Open source software information This device produced by Martem Ltd incl...

Reviews: