Adding devices 

By clicking on the 

 shortcut icon, a new device with default settings is 

added. It is also possible to add new devices with a right mouse click which 
makes the extended control menu to appear. 
 

 

 
 
 Add Devices dialog box appears.  
 

 
 
 
Set the Add Devices options:  

-  Number of devices to 

add 

-  Default settings or the 

device number from 
where the settings are 
derived  

-  Copy Object Also 

Click the Add button. 

 
Removing Devices 
To remove a device, select Remove Devices from the extended control menu 
or click on the shortcut icon. 
 

 

 
Select the range of the removed devices and click the Remove or Remove 
All 
button. The selected device is also removed after the warning dialog when   

 is clicked. 

Summary of Contents for TELEM-GW5

Page 1: ...Data Concentrator TELEM GW5 User Manual Martem AS 2009...

Page 2: ...NFIGURATION TOOL 12 10 1 Getting Started 12 10 2 GW5 Configuration Window 13 10 3 Tab Cards in the Configuration Window 14 10 3 1 Ports Tab Card 14 10 3 2 Devices Tab Card 16 10 3 3 Objects Tab Card 1...

Page 3: ...data exchange between the levels of the substation control system including setting values measurement values registered fault parameter values changes of state with associated time markings etc Data...

Page 4: ...Tallinn Fax 379 639 79 80 www martem ee Estonia 4 4 View Figure 4 a GW5 with Ethernet port b with optical port 5 Technical Data Data communication protocols To higher or lower level systems IEC 60870...

Page 5: ...n pulse minute pulse output open collector transistor Data communication parameters 1 start bit Odd even or no parity control Communication rates from 300 to 38400 bit sec asynchronous Configurable RT...

Page 6: ...igital output modul for 8 devices control 8 devices ELEM AI12G Analog input modul for 12 analog signals Time synchronisation TELEM moduls and data contcentrator are based on 16 bit DSP They have vario...

Page 7: ...LED TX Green LED at SSP port blinking indicates the existence of GPS time synchronization 9 Firmware Update Loading GW5 firmware from a PC computer is done through port 1 Switch 2 has to be set to ON...

Page 8: ...Data Concentrator TELEM GW5 Akadeemia tee 21G Tel 372 639 79 79 E mail martem martem ee 12618 Tallinn Fax 379 639 79 80 www martem ee Estonia 8 3 Open loader F2812SeriaFlash sdp 4 Open the Project tab...

Page 9: ...onia 9 5 Choose Com Do not use bigger than C3 Com 3 6 Show the way to the target If the gw5 out file is in the same catalogue as SDFlash exe the program that you use for firmware update then gw5 out i...

Page 10: ...Concentrator TELEM GW5 Akadeemia tee 21G Tel 372 639 79 79 E mail martem martem ee 12618 Tallinn Fax 379 639 79 80 www martem ee Estonia 10 7 Coff load Open the Buffer tab Coff Load 8 Reset Open the D...

Page 11: ...79 80 www martem ee Estonia 11 9 Start programming Open the Device tab Flash Start the Program If the connection with the target has failed then reset GW5 switch 1 and repeat the last step position 9...

Page 12: ...ere is no connection with the GW5 device then a warning message is displayed together with an alarm beep Figure 1 Stop sound button Stops the alarm sound The following parameters are shown for informa...

Page 13: ...uration Window To open the GW5 configuration window select Device GW5 RTA Setup from the user interface main menu Shortcut icons below the menu bar Open a new configuration Open a configuration file S...

Page 14: ...d button switches between tab cards Using the grid area Parameters can be selected or changed in the grid area cells Values of some cells can be changed directly and those of others via a list box or...

Page 15: ...on this channel Communication Mode Makes it possible to choose between the following handshaking options No control RTS CTS Control RTS Callout Request a Request by the RTS signal to the offline mode...

Page 16: ...or the chosen protocol type but you are still allowed to modify them 10 3 2 Devices Tab Card Figure 10 3 2 Devices tab card Up to 32 downlink devices can be connected to GW5 and configured on this tab...

Page 17: ...makes the extended control menu to appear Add Devices dialog box appears Set the Add Devices options Number of devices to add Default settings or the device number from where the settings are derived...

Page 18: ...indow always appears before removing operations are concluded Select Yes to accept or No to cancel the removal operation of the devices 10 3 3 Objects Tab Card Figure 10 3 3 Objects tab card The first...

Page 19: ...ox opens on clicking Subtypes of object and time marking mode can be selected Object type Format Time marking DI Digital input Single Double Without time With Short Time With Long Time With Short Time...

Page 20: ...ine GSM channel if the change in value is bigger than deadband 2 of full scale then a call to SCADA system is initiated Raw Min Raw Max Minimum and maximum raw values of analog measurement before scal...

Page 21: ...ed control menu appears When selecting Add Objects the following dialog box appears Removing Objects To remove a device click the button or select Remove Devices from the extended control menu When se...

Page 22: ...rmula Alarm The alarm LED number 1 16 on the LED Alarm panel which corresponds with the result of this formula Formula formula string Editing formulas Formulas can be created between the values of ana...

Page 23: ...into a double signal 201dbl 202 7 sin DI AI sin 301 0 cos DI AI cos 301 0 tan DI AI tan 301 0 arcsin DI AI arcsin 301 0 arccos DI AI arccos 301 0 arctan DI AI arctan 301 0 priority determines the ord...

Page 24: ...r The formulas of DI type of objects can contain AI values and floating point constants If the result of the formula is greater than 0 the value of the DI object is 1 if the result of the formula is l...

Page 25: ...mail martem martem ee 12618 Tallinn Fax 379 639 79 80 www martem ee Estonia 25 11 Common Main Menu 11 1 TCP IP Settings Only used for GW5 with Ethernet port to determine IP parameters 11 2 General Se...

Page 26: ...ttings Callout parameters Connection connecting timeout if the connection was not established during this time seconds GW5 will try to call out again Maximum connection duration if the connection is s...

Page 27: ...determined minimum and maximum ranges and the callout event is not forbidden for this input If the communication is initialized by GW5 it terminates the connection after all data is sent Scale Min Sc...

Page 28: ...DB9F 1 8 PC COM 8 1 Tx 422 Tx 422 Port 1 Port 2 7 Pin RTS CTS RxD TxD GND 2 3 4 5 6 7 GND Signal RJ45 8 1 Tx 422 Tx 422 Port 1 Port 2 7 Pin 1 5 2 3 Cable GW5 Telem RTU Cable GW5 PC COM port GW5 COM 2...

Page 29: ...difications Although the contents of this publication have been checked for conformity with the hardware and software described we cannot guarantee complete conformity since errors cannot be excluded...

Reviews: