background image

AS Martem 

Data Concentrator TELEM-GWM User Manual 

Rev. 2 / 2015 

 

 

AS MARTEM 

Tel: +372 639 7979 

martem@martem.eu

 

www.martem.eu

 

 

5

 - 

3. Technical Data

 

Data communication protocols

 

To higher level systems: 

  IEC 60870-5-104 

  IEC 60870-5-101 unbalanced and balanced, 

To lower level devices: 

  IEC 60870-5-104, 

  IEC 60870-5-103, 

  IEC 60870-5-101 Unbalanced, 

  Modbus-RTU, 

  Modbus-TCP, 

  IEC 62056-21 (IEC 1107), 

  SPA-Bus 

 

Communication ports

 

Communication ports may be freely configured for upper or lower level 

communication 

 

Base board 

  1 x Ethernet connection with RJ45 port. 1,5kV isolation 

  2 x RS-232 with RJ45 connector, galvanically isolated. 15 kV surge 

protection 

  2 x RS-485/232. RJ45 connector for RS-232 and screw terminals for 

RS-485, galvanically isolated. 15 kV surge protection 

  1 x Console mini USB port 

 

Expansion cards 

  Card D 

  8 optically isolated dry contact digital inputs (connected to dry contacts) 

  3 double digital outputs (relay contacts max. 0.3A 110VDC, 

 2A 30VDC, 0.5A 125VAC) 

 

Summary of Contents for TELEM-GWM

Page 1: ...KAUGJUHTIMISS STEEMID TELECONTROL SYSTEMS Data Concentrator TELEM GWM User Manual Martem AS 2016...

Page 2: ...INTRODUCTION 3 2 MAIN FEATURES 4 3 TECHNICAL DATA 5 4 COMMUNICATION CABLES 7 5 FIRMWARE UPDATE 8 6 DEFAULT SETUP INDICATION 9 7 NOTES 10 8 BLOCK DIAGRAM 11 9 ORDER CODE 12 10 OPEN SOURCE SOFTWARE INFO...

Page 3: ...th possibility for direct protocol translation from IEC 60870 5 101 to IEC 60870 5 104 and vice versa Cross referencing of data exchange protocols Creating transparent TCP IP to serial channels for re...

Page 4: ...ftware Defined Networking DPI Deep Packet Inspection Syslog Graphic Web Server A user friendly free configuration tool Configurable remotely over communication line Configuration export to ASCII CSV f...

Page 5: ...SPA Bus Communication ports Communication ports may be freely configured for upper or lower level communication Base board 1 x Ethernet connection with RJ45 port 1 5kV isolation 2 x RS 232 with RJ45...

Page 6: ...ates from 300 to 115200 bit sec Electrical characteristics of isolated input Dielectric withstand IEC 60255 5 Withstand to static discharge IEC 61000 4 2 Withstand to surges bursts IEC 61000 4 4 61000...

Page 7: ...8 RS 232 Telem Telem RS232 GW GW 8 7 2 6 3 5 4 4 5 3 6 2 7 1 RJ 45 Telem GPSTime 8 7 PPS 6 GND 5 RxD 4 TxD 3 9 30V 2 Tx 1 Tx Telem Telem GPSTime model with two optics GWM C1 4 3 3 5 2 6 RJ 12 Telem GP...

Page 8: ...not changed the password then default password is provided by Martem AS Press the Upd button next to SSH settings Press the pick button and select the copied update file file will be automatically un...

Page 9: ...2 Switch DFT SET back to OFF state when the alert indication LED is blinking to apply default setup If DFT SET is switched back to OFF state when the alert indication LED is not blinking default setu...

Page 10: ...ware and software described we cannot guarantee complete conformity since errors cannot be excluded The information provided in this manual is checked at regular intervals and any corrections that mig...

Page 11: ...AS Martem Data Concentrator TELEM GWM User Manual Rev 2 2015 AS MARTEM Tel 372 639 7979 martem martem eu www martem eu 11 8 Block diagram...

Page 12: ...ase model 2 Custom model Expansion card N No card D 8 DI and 3 DO E 16 DI and 6 DO L 3 x RJ45 LAN O 1 x RJ45LAN 2 x Optical LAN Modem card 0 No modem 1 3G modem 2 4G modem 10 Open source software info...

Reviews: