All material © 2007. Martin Audio Ltd. Subject to change without notice.
34
8.7
Limiter
At the end of the Engineer
Algorithm there is a three-
band limiter for the Low-Mid-
High bands.
The X-over frequencies
between the bands are
determined by the X-
frequencies from the
Automated EQ section.
The Headroom parameter
sets the limiter threshold as
a function of the Target
Volume. E.g. when the
Headroom parameter is set
to 3dB, then the level is
allowed to be 3dB higher
than the target volume
before the limiter starts
working.
The limiters release time is
set in milliseconds, the
limiters attack time is set as
a function of the release.