5
After selecting the desired depth and offset settings, attach the UMO
-
100 to the mount using two
1/2”
X
3”
flange bolts, and Flange locknuts, provided for you. If you purchased the optional SmartCean System, you
will install the SmartClean cylinder top brackets on the side of the mount flanges. Use the
1/2”
X 3
1/2”
bolts
provided in place of the
3”
bolts. The SmartClean cylinder top brackets are available in right and left sets.
*
The right set mounts on the left UMO
-
100 and the left set mounts on the right UMO
-
100. The correct con-
figuration will bring the bracket pin point to the center of the row cleaner.
Torque the bolts to 80 ft
-
lbs.
*NOTE:
Confirm half of UMO
’
s are left sided and half are right sided for proper planter drafting.
STEP 3 : ATTACH UMO-100 TO THE MOUNT
Right UMO
-
100 and Left SmartClean Cylinder
top bracket set are shown
SmartClean BRACKET SET (SC
-
CUB
-
2L)