background image

This  is  an  unvented  gas-fired  heater. 
It  uses  air  (oxygen)  from  the  room 
in  which  it  is  installed.  Provisions  for 
adequate  combustion  and  ventilation 
air must be provided. Refer to page 9. 

READ AND SAVE THESE INSTRUCTIONS

WARNINGS

If  the  information  in  this  manual  is  not  followed 
exactly,  a  fire  or  explosion  may  result  causing 
property damage, personal injury or loss of life.

–  Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 
other appliance.

–  WHAT TO DO IF YOU SMELL GAS

 

•  Do not try to light any appliance.

 

•  Do not touch any electrical switch; do not use 

any phone in your building.

 

•  Immediately  call  your  gas  supplier  from  a 

neighbor's  phone.  Follow  the  gas  supplier's 
instructions.

 

•  If you cannot reach your gas supplier, call the 

fire department.

–  Installation  and  service  must  be  performed  by 

a  qualified  installer,  service  agency  or  the  gas 
supplier.

MODEL: 33ISD

Natural Gas or Propane/LPG

Control Type: Milli-Volt or T-Stat

VENT-FREE FIREPLACE SYSTEMS 

INSTALLATION AND OPERATING INSTRUCTIONS

WARNINGS

This  appliance  may  be  installed  in  an 
aftermarket, permanently located, man-
ufactured  (mobile)  home,  where  not 
prohibited by local codes.
This appliance is only for use with the 
type of gas indicated on the rating plate. 
This appliance is not convertible for use 
with other gases.

f i r e - p a r t s . c o m

Summary of Contents for 33ISD

Page 1: ...y electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call t...

Page 2: ...nts 11 Fireplace Framing 14 Securing Heater to Floor 15 Connecting the Gas 16 Checking Gas Pressure 18 Electrical Wiring Milli Volt 19 Electrical Wiring Fan 21 Log Placement 22 Flame Appearance 23 Che...

Page 3: ...refully before installing or trying to operate this vent free gas heater IMPORTANT SAFETY INFORMATION 8 CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the u with hea...

Page 4: ...2 psig 3 5 kPa 22 The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures...

Page 5: ...RATION This unvented gas heater requires no outside venting and burns cleanly with high heating ef ciency Piezo Ignitor Fireplace Screen Control Knobs PRODUCT FEATURES Optional Face Plate Figure 1 Unv...

Page 6: ...gas to the gas logs is shut off at the valve IGN Valve position to light maintain a standing pilot ON Valve position to turn ON OFF log set with remote switch thermostat LOW HI Variable position to co...

Page 7: ...tat with 15 wire Hand held Thermostat Remote with Receiver Thermostat Sensor Handle the gas log burner assembly by the grate only Do not pick the unit up by the burners Gloves are recommended when han...

Page 8: ...y with the holes in the top frame assembly See Figure 3 3 Install the ve 5 screws in owner s manual packaging which attach the canopy to the top frame assembly See Figure 3 4 Tighten all screws Make s...

Page 9: ...c feet per 1 000 BTU per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed th...

Page 10: ...ion would be based only on the room with the heater BTU Hr 151 2 x 12 x 8 50 GENERAL INSTALLATION INFORMATION Figure 4 Example of a Large Room with 1 2 Wall Divider Counter Fireplace x 1000 x 1000 528...

Page 11: ...ire width and depth of the base Mantel clearances The canopy supplied with the unit must be installed If a combustible mantel is installed It must meet the clearance requirements shown in Figure 8 The...

Page 12: ...own in Figure 7 CLEARANCES and HEIGHT REQUIREMENTS Example Amantel may project from the wall a maximum of 21 2 at minimum of 8 above the opening and a maxi mum of 12 at a mini mum of 26 above the open...

Page 13: ...must be installed at least 5 above any combustible ooring material such as carpeting or tile which is closer than 14 to the base of the replace See to Figures 10 and 11 Figure 10 Minimum Clearance ab...

Page 14: ...ce dimensions The framing headers may not rest directly on top of the rebox The replace may be installed directly on a combustible oor or a raised platform of an appropriate height Do not place replac...

Page 15: ...as shown in Figure 16 4 Lift grate and base assembly out of the rebox SECURING HEATER TO FLOOR Lift grate and base assembly using the grate only CAUTION 4 Secure the rebox with two anchoring screws 3...

Page 16: ...Hr Undue pressure loss will occur if the pipe is too small A manual shutoff valve must be installed upstream of the appliance Union tee and plugged 1 8 NPT pressure tapping point should be installed...

Page 17: ...door Figure 1 page 5 If the gas supply is different DO NOT INSTALL the heater Contact your dealer for the correct model Connecting to the wrong gas type may result in property damage or personal inju...

Page 18: ...ter taking pressure reading reinstall test plug Check for gas leaks MILLIVOLT CONTROL Figure 22 The valve regulator controls the burner pressure which should be checked at the pressure test point Turn...

Page 19: ...ING OPTIONAL WALL SWITCH OR THERMOSTAT 1 Use 18 awg two wire cable 15 feet maximum length 2 At one end of the cable connect both wires to the wall switch or thermostat At the other end connect one wir...

Page 20: ...d with a milli volt meter having a 0 1000 mV range Conduct each check shown in chart below by connection meter test leads to terminals as indicated CONNECTING REMOTE RECEIVER THESE INSTRUCTIONS SUPERC...

Page 21: ...MPORTANT Always check local building codes The installation must comply with local regulations as well as the national electric codes This replace has a three prong grounded electrical plug This plug...

Page 22: ...l logs or embellishments such as pine cones vermiculite or rock wool to the heater Only use the logs supplied with the unit Failure to position the parts in accordance with diagrams below or to use on...

Page 23: ...correct pilot ame If the pilot ame does not touch the thermocouple then the main burner cannot function reliably See Figures 28 and 30 for incorrect shape of pilot ame THERMOSTAT AND MILLI VOLT Figur...

Page 24: ...roper burning will result During manufacturing fabricating and shipping various components of this appliance are treated with certain oils lms or bonding agents These chemicals are not harmful but may...

Page 25: ...plier s instructions If you cannot reach your gas supplier call the re department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by h...

Page 26: ...t of the gas piping 7 With the control knob pushed in push in and release the piezo ignitor button to light the pilot 8 Continue pushing the control knob in for a further 10 seconds to prevent the ame...

Page 27: ...iezo ignitor MATCH LIGHTING INSTRUCTIONS Figure 35 Location of Blower Control OPERATING INSTRUCTIONS AND BLOWER OPERATION Locate the blower control by opening control access door The variable controll...

Page 28: ...place ignitor 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing 5 Replace ignitor cable 6 Replace piezo ignitor 1 Ventilate room Stop using odor causing products while h...

Page 29: ...high 1 Power cord not plugged in 2 Loose wire connections 3 Defective blower thermostat REMEDY 1 Press in control knob fully 2 After ODS pilot lights keep control knob pressed in for 30 seconds 3 Ful...

Page 30: ...loth ANNUAL CLEANING INSPECTION Refer to parts diagram for location of items discussed below Inspect and clean burner air intake holes Remove lint or particles with vacuum brush or pipe cleaners Failu...

Page 31: ...re to use only parts speci cally approved with this appliance may result in property damage or personal injury WARNING Item Description Qty 18 32VF 24 36VP 30 42VF 1 Rear Log 1 53D1500 53D1505 53D1510...

Page 32: ...14 12 Failure to position the parts in accordance with these diagrams or failure to use only parts speci cally approved with this appliance may result in property damage or personal injury WARNING IL...

Page 33: ...ter Simulated Brick 23D7047 1 Control Door Assembly 23D6013K OPTIONAL FACE PLATE 8 1 33 x 43 Black Face Plate Kit DIFACESM 8 1 36 x 50 Black Face Plate Kit DIFACELG 9 1 Small Top Trim 23D2002 9 1 Larg...

Page 34: ...ILLUSTRATED PARTS BREAKDOWN Failure to position the parts in accordance with these diagrams or failure to use only parts speci cally approved with this appliance may result in property damage or pers...

Page 35: ...716 53D0716 7 ODS Pilot Assembly 1 26D2529 26D2530 8A Pilot On Off 1 14D0473 14D0477 Knob Extension 1 37D0010 37D0010 8B Hi Lo Knob Extension 1 37D0011 37D0011 9 Rear burner Injector 1 53D0712 53D0714...

Page 36: ...instructions The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to...