14
Installation
• Replacing the supplied cable with one that connects directly inside the
fixture.
The Exterior 200 is equipped with a 1.8-meter (5.9 ft.) length of 3-conductor
0.75 mm
2
(~18 AWG) weatherproof electrical cable for connection to the AC
power supply. The cable enters the fixture through a cable gland that fits 5.5
- 10 mm diameter cables. The cable attaches with 1/4” female spade plugs
on the live and neutral wires and a ring terminal on the ground wire.
Replacing the mains lead
Other cable can be installed as follows.
1 Isolate the fixture from AC power.
2 Loosen both cable gland cap nuts and remove the power section cover.
Disconnect the existing mains cable and pull it through the cable gland.
3 Pass the new cable through the cable gland and connect the leads. The live
wire connects to PL3, the neutral wire connects to PL1, and the ground wire
connects to the chassis screw terminal.
4 Draw up the slack in the AC and data cables and replace the power section
cover. Tighten the cable gland cap nuts well to seal against moisture.
Installing a cord cap on the mains lead
A non-IP-rated cord cap may be installed on the mains lead for testing,
service, and temporary applications. For outdoor installations an IP65-rated
cord cap can be used.
Following the cord cap manufacturer’s instructions, connect the yellow and
green wire to ground (earth), the brown wire to live, and the blue wire to
neutral. Table 3 shows some pin identification schemes; consult an
electrician if you have any doubts about proper installation.
Wire (EU)
Wire (US)
Pin
Marking
Screw (US)
brown
black
live “L”
yellow
or
brass
blue
white
neutral
“N”
silver
yellow/green green
ground green
Table 3: Cord Cap Connections
Summary of Contents for Exterior 200
Page 1: ...Exterior 200 user manual mar tinar chi tect ura l ...
Page 5: ...5 SECTION 1 GETTING STARTED ...
Page 27: ...General operation 27 SECTION 2 STAND ALONE OPERATION ...
Page 48: ...48 Synchronous triggering during Stand Alone operation ...
Page 49: ...Synchronous triggering during Stand Alone operation 49 SECTION 3 DMX CONTROL ...
Page 53: ...DMX Controller operation 53 SECTION 4 OPTICS ...
Page 57: ...Lens options 57 SECTION 5 SERVICE AND TROUBLESHOOTING ...
Page 65: ...SECTION 6 REFERENCE ...
Page 75: ......