38
Programming using an MP-2 Uploader
4 Select
E X T 2 0 0 v e r .
x . x
. (Note that
x . x
is the number that
corresponds to the firmware level that is loaded in the fixture. The installed
firmware version number is displayed by the LEDs on power up. The
number of red flashes in LED 1 indicates the digit to the left of the decimal
point and the number of green flashes in LED 2 indicates the digit to the
right of the decimal point. For example, if the firmware version is 1.3, LED 1
flashes red once and LED 2 flashes green three times.)
5 Select
F i x t u r e m e n u
. It is from this point you use the keys on the
uploader to navigate and select the desired menu item. For further guidance
see the following sections.
Selecting fixtures to program
Before selecting any fixture to program you must have set its control
address. If you have not yet done so, follow the instructions described in
“DMX address” on page 22.
You have the option of programing all the Exterior 200s on a data link, or an
individual Exterior 200. Fixture-specific settings such as the control address
should be made in single-fixture mode. If no other fixtures are connected,
however, then all-fixtures mode may be used. Global settings are made
easiest in all-fixtures mode. For example, it might be appropriate to program
the time, or trigger criteria into all fixtures simultaneously, while program
scenes might be programmed into fixtures individually.
Note that it is important that all the fixtures have the same software level set,
or the results will be unpredictable. For more information see, “Firmware
updates” on page 61.
Selecting a single fixture
To program a single fixture:
1 Select
S i n g l e a d d r e s s
from the Fixture menu.
2 Select a start address that corresponds to the fixture that you want to
program using the arrows.
3 Select
O K
.
Selecting all Fixtures on a data link
To program all fixtures on the data link simultaneously,
s
elect
A l l
a d d r e s s e s
from the Fixture menu.
Summary of Contents for Exterior 200
Page 1: ...Exterior 200 user manual mar tinar chi tect ura l ...
Page 5: ...5 SECTION 1 GETTING STARTED ...
Page 27: ...General operation 27 SECTION 2 STAND ALONE OPERATION ...
Page 48: ...48 Synchronous triggering during Stand Alone operation ...
Page 49: ...Synchronous triggering during Stand Alone operation 49 SECTION 3 DMX CONTROL ...
Page 53: ...DMX Controller operation 53 SECTION 4 OPTICS ...
Page 57: ...Lens options 57 SECTION 5 SERVICE AND TROUBLESHOOTING ...
Page 65: ...SECTION 6 REFERENCE ...
Page 75: ......