62
Service
Boot sector upload
If the normal upload procedure does not work, or if the software update
notes call for a boot sector update, move the boot sector jumper at PL2 to
the BOOT position before uploading software.
Performing a boot sector update
1 Make sure the Exterior 200 is isolated from AC power. Open the power
section.
2 Locate the jumper at position PL2. Move the jumper to the “BOOT” position
(pins 1 and 2).
3 Perform a boot mode upload as described in the uploader manual.
4 When the upload is complete, disconnect the fixture from power and move
the jumper at PL2 back to the “LOCK” position (pins 2 and 3).
5 To replace the cover see “Seals and torque settings” on page 58.
Fuse replacement
Warning!
Never replace fuses with ones of a different rating!
The Exterior 200 has 3 fuses located in the power section. The main fuse is
located on the small circuit board and the secondary fuses for the low-
voltage power supplies are located on the main circuit board.
Fuse replacement requires a 4 mm Allen wrench and an 8 mm wrench.
To replace a fuse:
1 Make sure the Exterior 200 is isolated from AC power.
2 Open the power section.
3 Remove the two bolts at the rear of the power module and then slide the
entire module out of the housing.
4 Locate and replace the defective fuse with one of the same size and rating.
5 Replace and secure the module. Replace the cover before applying power.
(See “Seals and torque settings” on page 58.)
Summary of Contents for Exterior 200
Page 1: ...Exterior 200 user manual mar tinar chi tect ura l ...
Page 5: ...5 SECTION 1 GETTING STARTED ...
Page 27: ...General operation 27 SECTION 2 STAND ALONE OPERATION ...
Page 48: ...48 Synchronous triggering during Stand Alone operation ...
Page 49: ...Synchronous triggering during Stand Alone operation 49 SECTION 3 DMX CONTROL ...
Page 53: ...DMX Controller operation 53 SECTION 4 OPTICS ...
Page 57: ...Lens options 57 SECTION 5 SERVICE AND TROUBLESHOOTING ...
Page 65: ...SECTION 6 REFERENCE ...
Page 75: ......