AFETY

 

PRECAUTIONS

The Juggler is not for household use. It is not a toy: it presents risks of serious
injury due to electric shock, high heat, and intense light. For safe operation, read
this manual before using the fixture and observe all warnings and precautions
printed here and on the fixture. If you have questions about how to operate the
fixture safely, please contact your Martin distributor or dealer.

For protection against dangerous electric shock, always ground (earth) the 
fixture electrically. Use only a source of AC power that complies with local 
building and electrical codes.

Replace the lamp if it becomes defective or worn out. Allow the fixture to cool 
for 5 minutes before installing a new lamp.

Keep all combustible materials (for example fabric, wood, paper) at least 30 
cm (12 inches) away from the fixture. Keep flammable materials well away 
from the fixture.

Provide a minimum clearance of 10 cm (4 inches) around the fan and air vent. 

When suspending the fixture above ground level, verify that the structure can 
hold at least 10 times the weight of all installed devices and secure the fixture 
with an approved safety cable. Block access below the work area whenever 
installing or removing the fixture. 

Never remove any cover except the lamp access cover. Refer all service to a 
qualified technician. 

Do not expose the fixture to rain or moisture.

Do not illuminate surfaces within 1 m (39 inches) of the fixture.

Do not operate the fixture if the ambient temperature exceeds 40° C 
(104° F).

NEVER place filters or other objects over the lens or mirror. 

Summary of Contents for Juggler

Page 1: ...Juggler user manual ...

Page 2: ......

Page 3: ...music UNPACKING The packing material is carefully designed to protect the fixture during shipment always use it to transport the fixture The Juggler comes with 500 hour halogen lamp installed mounting bracket 1 5 meter 3 wire IEC power cable user manual 1 mounting bracket 2 swivel locks 3 focus adjustment 4 lamp access 5 clamp hole 6 air vent 7 AC input main fuse P N 35000040 Revision F 1999 2002 ...

Page 4: ... for 5 minutes before installing a new lamp Keep all combustible materials for example fabric wood paper at least 30 cm 12 inches away from the fixture Keep flammable materials well away from the fixture Provide a minimum clearance of 10 cm 4 inches around the fan and air vent When suspending the fixture above ground level verify that the structure can hold at least 10 times the weight of all inst...

Page 5: ...sconnect the fixture from AC power If replacing a lamp allow it to cool for 5 minutes before removing the lamp access cover The lamp cools faster with the cover in place 2 Remove both screws from the lamp access cover and lift the cover off 3 Grasp the old lamp by the reflector and pull it out of the holder Then pull the socket off the lamp Do not pull the wires 4 Push the socket fully onto the pi...

Page 6: ... is installed and connected the focus may be adjusted by loosening and sliding the focus adjustment knob Warning Block access below the work area before proceeding Always use a secure means of secondary attachment To install or hang the Juggler 1 Install the mounting bracket on the chassis as shown Place the washers on the stud before the bracket 2 Verify that the structure can support at least 10...

Page 7: ...t 0 1 meters 4 in from any combustible materials Verify that the clearance around the air vent and lamp access plate is at least 0 1 meters 4 in To use the bracket as a floor stand The Juggler may be placed on the floor by standing it squarely on the mirror end or with the support of the mounting bracket Never lay the fixture flat on its back 1 Optional Install the mounting bracket as described ab...

Page 8: ... closely matches the AC supply voltage before applying power Contact your Martin dealer if the voltage on the label differs from the AC mains voltage by more than five percent The lamp turns on as soon as power is applied The effects start moving as soon as sound is picked up by the built in microphone An Automatic Gain Control AGC adjusts sensitivity when the average sound pressure alters Note Al...

Page 9: ...ber label T R O U B L E SH O O T I N G If these remedies do not solve the problem contact your Martin dealer for service problem probable cause s suggested remedy No light No power to the fixture Check connections Blown fuse Replace fuse Burned out lamp Install new lamp Fixture overheating Allow to cool Improve air flow around fixture No action Sound too low to activate control circuit Increase vo...

Page 10: ...e EU version 2 5 AT 250 V P N 05020010 Primary fuse US version 5 0 AT 250 V P N 05020018 Minimum distance to combustible materials 0 3 m 12 in Minimum distance to illuminated surfaces 1 0 m 39 in Minimum clearance around fan and air vents 0 1 m 4 in ACCESSORIES Martin DMX Switch Pack 210 245 V 90758200 Martin DMX Switch Pack 100 130 V 90758300 Osram 24V 250W ELC 50 h halogen lamp 97000104 Philips ...

Page 11: ......

Reviews: