© Martin Engineering GmbH
26
M3682UK-09/17
Installation
5.2.4
Centring the mainframe beneath the conveyor belt
Tab. 8: Centring the secondary cleaner beneath the conveyor belt
1. Measure the clearances (A) and (B) between the edge of the
cleaning elements and the conveyor belt edge.
2. Shift the secondary cleaner so that clearance A is equal to
clearance B.
Fig. 20:
Item
Description
1
Chute wall
2
Driving drum
3
Blades
NOTE
The conveyor belt must protrude around 50 to 100 mm from the
left and right sides. The cleaning elements must be centrally
aligned beneath the conveyor belt.
1
A
A
2
3