© Martin Engineering GmbH
26
M3504UK-10/15
Maintenance
4. Fold the scraper forward.
5. Remove the safety clip (3, Fig.10).
6. Remove the scraper blade (2, Fig.10) by pulling the entire blade
toward the operator side (with light hammer blows if neces-
sary).
7. Install the new blade in reversed order.
8. Place the scrapers against the drum head again.
9. If the spring tensioner was dismantled, reinstall it as described
in the operating manual for the spring tensioner.
10. Loosen the locking screws (1, Fig.10) on the spring tensioner
and fix the locking sleeve.
11. Check the installation as described in section 4.4 Installation
check-list.
12. Tension the scraper (refer to the operating manual of the re-
spective spring tensioner for the tension specifications).
13. Remove all tools from the working area.
14. Turn the conveyor system on again.
15. Monitor the cleaner and test its cleaning performance.