To return to autoranging hold the RANGE button for 2 seconds.
3.11 AC & DC Voltage Measurement
Connect the black test lead to the COM terminal and the red test
lead to the %HzV
Ω
terminal.
Set the rotary switch to either AC mV/V or DC mV/V and if
required manually set the range.
Taking all necessary safety precautions connect the test leads to
the circuit being measured and read the measured voltage from
the display.
3.12 AC & DC Current Measurement
Connect the black test lead to the COM terminal and the red test
lead to the μA mA or 10A terminal depending on the magnitude of
current to be measured.
Set the rotary switch to either the AC or DC ranges as required.
Taking all necessary safety precautions connect the test leads
in series with the circuit being measured and read the measured
current from the display.
3.13 Resistance Measurement
Connect the black test lead to the COM terminal and the red test
lead to the %HzV
Ω
terminal.
Set the rotary switch to
Ω
and if required manually set the range.
Taking all necessary safety precautions connect the test leads to
the circuit being measured and read the measured resistance from
the display.